Literature DB >> 8880539

Assessment of enzyme immunoassay versus radioimmunoassay for detection of Legionella pneumophila serogroup 1 antigen in frozen urine specimens.

F Y Chang1, J E Stout, V L Yu.   

Abstract

An enzyme immunoassay (EIA) was compared with a radioimmunoassay (RIA) for detection of Legionella pneumophila serogroup 1 antigen in 37 frozen urine samples. Among 18 samples positive by the RIA at the time of collection, 50% (9 of 18) of stored specimens retained positivity when retested by the RIA whereas 78% (14 of 18) of stored specimens retained positivity when retested by the EIA (P < 0.02). A false-negative result occurred after storage for 5 months or less if the original RIA result showed weak positivity.

Entities:  

Mesh:

Year:  1996        PMID: 8880539      PMCID: PMC229340          DOI: 10.1128/jcm.34.10.2628-2629.1996

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  6 in total

1.  Prevalence and diagnosis of Legionella pneumonia: a 3-year prospective study with emphasis on application of urinary antigen detection.

Authors:  B Ruf; D Schürmann; I Horbach; F J Fehrenbach; H D Pohle
Journal:  J Infect Dis       Date:  1990-12       Impact factor: 5.226

2.  Reevaluation of the definition of Legionnaires' disease: use of the urinary antigen assay. Community Based Pneumonia Incidence Study Group.

Authors:  J F Plouffe; T M File; R F Breiman; B A Hackman; S J Salstrom; B J Marston; B S Fields
Journal:  Clin Infect Dis       Date:  1995-05       Impact factor: 9.079

3.  Rapid diagnosis of Legionnaires' disease by urinary antigen detection. Comparison of ELISA and radioimmunoassay.

Authors:  B Sathapatayavongs; R B Kohler; L J Wheat; A White; W C Winn; J C Girod; P H Edelstein
Journal:  Am J Med       Date:  1982-04       Impact factor: 4.965

4.  Retrospective evaluation of the Du Pont radioimmunoassay kit for detection of Legionella pneumophila serogroup 1 antigenuria in humans.

Authors:  M E Aguero-Rosenfeld; P H Edelstein
Journal:  J Clin Microbiol       Date:  1988-09       Impact factor: 5.948

5.  Comparison of Binax Legionella Urinary Antigen EIA kit with Binax RIA Urinary Antigen kit for detection of Legionella pneumophila serogroup 1 antigen.

Authors:  B A Hackman; J F Plouffe; R F Benson; B S Fields; R F Breiman
Journal:  J Clin Microbiol       Date:  1996-06       Impact factor: 5.948

6.  Rapid radioimmunoassay diagnosis of Legionnaires' disease: detection and partial characterization of urinary antigen.

Authors:  R B Kohler; S E Zimmerman; E Wilson; S D Allen; P H Edelstein; L J Wheat; A White
Journal:  Ann Intern Med       Date:  1981-05       Impact factor: 25.391

  6 in total
  5 in total

1.  Comparison of diagnostic sensitivities of three assays (Bartels enzyme immunoassay [EIA], Biotest EIA, and Binax NOW immunochromatographic test) for detection of Legionella pneumophila serogroup 1 antigen in urine.

Authors:  Carmen Guerrero; Carmen M Toldos; Genoveva Yagüe; Cristobal Ramírez; Tomás Rodríguez; Manuel Segovia
Journal:  J Clin Microbiol       Date:  2004-01       Impact factor: 5.948

2.  Comparison of radioimmunoassay and enzyme immunoassay kits for detection of Legionella pneumophila serogroup 1 antigen in both concentrated and nonconcentrated urine samples.

Authors:  J A Domínguez; L Matas; J M Manterola; R Blavia; N Sopena; F J Belda; E Padilla; M Giménez; M Sabrià; J Morera; V Ausina
Journal:  J Clin Microbiol       Date:  1997-06       Impact factor: 5.948

3.  Evaluation of the bioNexia Legionella Test, Including Impact of Incubation Time Extension, for Detection of Legionella pneumophila Serogroup 1 Antigen in Urine.

Authors:  Paul Badoux; Sjoerd M Euser; Jacob P Bruin; Patrick P G Mulder; Ed P F Yzerman
Journal:  J Clin Microbiol       Date:  2017-03-22       Impact factor: 5.948

Review 4.  Legionella and Legionnaires' disease: 25 years of investigation.

Authors:  Barry S Fields; Robert F Benson; Richard E Besser
Journal:  Clin Microbiol Rev       Date:  2002-07       Impact factor: 26.132

5.  Comparison of the ImmuView and the BinaxNOW antigen tests in detection of Streptococcus pneumoniae and Legionella pneumophila in urine.

Authors:  S Athlin; A Iversen; V Özenci
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2017-06-06       Impact factor: 3.267

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.