Literature DB >> 8880104

Gastric intramucosal pH: an indicator of weaning outcome from mechanical ventilation in COPD patients.

G Bouachour1, M P Guiraud, J P Gouello, P M Roy, P Alquier.   

Abstract

The aim of this study was to determine whether gastric intramucosal pH (pHim) and/or gastric intramucosal carbon dioxide tension (PCO2,im) measured by tonometry can be used to predict the success of weaning in chronic obstructive pulmonary disease (COPD) patients. Twenty six consecutive COPD patients, undergoing mechanical ventilation for acute respiratory failure and satisfying the criteria of weaning from mechanical ventilation with nasogastric tonometer in place, were studied. Arterial blood gas values and PCO2,im were measured 24 h before (H-24), just before (H0), and after 20 min of a weaning trial on T-piece (H20min). Weaning failure was defined as the development of respiratory distress and/or arterial blood gas impairments during the first 2 h of spontaneous breathing on T-piece, or reintubation within 24 h after extubation. Between the weaning failure (n = 6) and weaning success (n = 20) groups, there were no differences in blood gas analysis readings at H-24 and H0 before the weaning period, age, Simplified Acute Physiology Score (SAPS) on admission, SAPS on the day of weaning trial, and duration of ventilation. Clinical status, tonometric and arterial gasometric data were similar at H-24 and H0 in all patients. During mechanical ventilation, pHim was < or = 7.30 in patients who failed weaning and > 7.30 in patients who were successfully weaned (p < 0.001; 100% sensitivity and specificity). The threshold value for PCO2,im of 8.0 kPa (60 mmHg) represents a clear demarcation with respect to outcome before the weaning trial. PCO2,im values during mechanical ventilation are significantly different (p < 0.001) between patients who were successfully weaned and those who were not (6.9 +/- 0.9 vs 9.9 +/- 1.1 kPa (51.9 +/- 6.7 vs 74.3 +/- 8.0 mmHg, respectively)). At H20min, pHim and PCO2,im were still statistically different between the weaning failure and the weaning success group. We conclude that measurement of gastric intramucosal pH (or gastric intramucosal carbon dioxide tension) represents a simple and accurate index to predict weaning outcome in chronic obstructive pulmonary disease patients before attempting weaning.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8880104     DOI: 10.1183/09031936.96.09091868

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  7 in total

Review 1.  Variable performance of weaning-predictor tests: role of Bayes' theorem and spectrum and test-referral bias.

Authors:  Martin J Tobin; Amal Jubran
Journal:  Intensive Care Med       Date:  2006-11-08       Impact factor: 17.440

2.  Differential cardiovascular responses during weaning failure: effects on tissue oxygenation and lactate.

Authors:  Spyros Zakynthinos; Christina Routsi; Theodoros Vassilakopoulos; Panagiotis Kaltsas; Epaminondas Zakynthinos; Danai Kazi; Charis Roussos
Journal:  Intensive Care Med       Date:  2005-10-25       Impact factor: 17.440

3.  Esophageal capnometry during hemorrhagic shock and after resuscitation in rats.

Authors:  Balagangadhar R Totapally; Harun Fakioglu; Dan Torbati; Jack Wolfsdorf
Journal:  Crit Care       Date:  2002-12-20       Impact factor: 9.097

4.  Gastro-oesophageal reflux disease increases the risk of intensive care unit admittance and mechanical ventilation use among patients with chronic obstructive pulmonary disease: a nationwide population-based cohort study.

Authors:  Chen-Liang Tsai; Yu-Huei Lin; Meng-Ting Wang; Li-Nien Chien; Chii Jeng; Chih-Feng Chian; Wann-Cherng Perng; Chi-Huei Chiang; Hung-Yi Chiou
Journal:  Crit Care       Date:  2015-03-24       Impact factor: 9.097

5.  Clinical verification of a clinical decision support system for ventilator weaning.

Authors:  Jiin-Chyr Hsu; Yung-Fu Chen; Wei-Sheng Chung; Tan-Hsu Tan; Tainsong Chen; John Y Chiang
Journal:  Biomed Eng Online       Date:  2013-12-09       Impact factor: 2.819

6.  High levels of B-type natriuretic peptide predict weaning failure from mechanical ventilation in adult patients after cardiac surgery.

Authors:  Thiago Martins Lara; Ludhmila Abrahao Hajjar; Juliano Pinheiro de Almeida; Julia Tizue Fukushima; Carmem Silvia Valente Barbas; Adriano Rogerio Baldacin Rodrigues; Emilia Nozawa; Maria Ignes Zanetti Feltrim; Elisangela Almeida; Vera Coimbra; Eduardo Osawa; Rafael de Moraes Ianotti; Alcino Costa Leme; Fabio Biscegli Jatene; Jose Otavio Costa Auler; Filomena Regina Barbosa Gomes Galas
Journal:  Clinics (Sao Paulo)       Date:  2013-01       Impact factor: 2.365

7.  Cerebral cortex and respiratory muscles perfusion during spontaneous breathing attempts in ventilated patients and its relation to weaning outcomes: a protocol for a prospective observational study.

Authors:  Daniel Langer; Greet Hermans; Zafeiris Louvaris; Marine Van Hollebeke; Alexander Dhaenens; Maarten Vanhemelen; Philippe Meersseman; Joost Wauters; Rik Gosselink; Alexander Wilmer
Journal:  BMJ Open       Date:  2019-10-31       Impact factor: 2.692

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.