Resiting Molteno implant tubes.

F Billson1, R Thomas, J Grigg.   

Abstract

The authors describe a surgical technique for resiting Molteno implant tubes. The indications for this intervention are a blockage of the tube that cannot be resolved by other means; erosion of the scleral flap and conjunctiva by the tube; and pediatric cases in which enlargement of the eye causes retraction of the tube from the anterior chamber.

Mesh:

Year:  1996        PMID: 8878203

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers        ISSN: 1082-3069


  2 in total

1.  Extension of a retracted ciliary sulcus tube of Ahmed glaucoma implant with angiocatheter segment.

Authors:  Sasan Moghimi; Massood Mohammadi
Journal:  Int Ophthalmol       Date:  2012-05-05       Impact factor: 2.031

2.  Tube-in-tube: A Solution for Retracted Tube.

Authors:  Surinder S Pandav; Natasha Gautam; Faisal Thattaruthody
Journal:  J Curr Glaucoma Pract       Date:  2021 Jan-Apr
  2 in total