STUDY OBJECTIVE: To reevaluate whether it is possible to reliably differentiate malignant mediastinal lymph nodes from benign nodes by size, and to determine the frequency of metastases to normal-sized mediastinal lymph nodes that directly affects the sensitivity for detecting malignant mediastinal lymph nodes (N2 nodes) on CT. DESIGN: Prospective study of patients with non-small cell lung cancer. SETTING: Department of Radiology and First Department of Surgery, Yamaguchi University School of Medicine. PATIENTS: We examined 40 patients with non-small cell lung cancer, who underwent thoracotomy because of operable stage (stage I, II, IIIA) in preoperative staging, using CT and transesophageal echocardiography (TEE). INTERVENTIONS: None. MEASUREMENTS AND RESULTS: Lymph nodes 10 mm or greater in short-axis diameter on CT and TEE were considered abnormal. Furthermore, lymph node size was measured by TEE and nodal specimens in long- and short-axis diameter in each patient. Two hundred eight mediastinal lymph nodes were dissected and N2 nodes were present in 28% of patients (11/40); in 7 of these 11 patients (64%), mediastinal lymph node metastases were misdiagnosed on CT because of normal-sized N2 nodes. Furthermore, in 73% of N2 nodes, nodal size was normal on TEE. There were no significant difference in both diameters between malignant mediastinal lymph nodes and benign nodes on TEE and nodal specimens. CONCLUSIONS: It is not possible to reliably differentiate malignant mediastinal nodes from benign nodes by size alone, and we should be aware of high frequency of normal-sized N2 nodes in patients with operable stage of lung cancer.
STUDY OBJECTIVE: To reevaluate whether it is possible to reliably differentiate malignant mediastinal lymph nodes from benign nodes by size, and to determine the frequency of metastases to normal-sized mediastinal lymph nodes that directly affects the sensitivity for detecting malignant mediastinal lymph nodes (N2 nodes) on CT. DESIGN: Prospective study of patients with non-small cell lung cancer. SETTING: Department of Radiology and First Department of Surgery, Yamaguchi University School of Medicine. PATIENTS: We examined 40 patients with non-small cell lung cancer, who underwent thoracotomy because of operable stage (stage I, II, IIIA) in preoperative staging, using CT and transesophageal echocardiography (TEE). INTERVENTIONS: None. MEASUREMENTS AND RESULTS: Lymph nodes 10 mm or greater in short-axis diameter on CT and TEE were considered abnormal. Furthermore, lymph node size was measured by TEE and nodal specimens in long- and short-axis diameter in each patient. Two hundred eight mediastinal lymph nodes were dissected and N2 nodes were present in 28% of patients (11/40); in 7 of these 11 patients (64%), mediastinal lymph node metastases were misdiagnosed on CT because of normal-sized N2 nodes. Furthermore, in 73% of N2 nodes, nodal size was normal on TEE. There were no significant difference in both diameters between malignant mediastinal lymph nodes and benign nodes on TEE and nodal specimens. CONCLUSIONS: It is not possible to reliably differentiate malignant mediastinal nodes from benign nodes by size alone, and we should be aware of high frequency of normal-sized N2 nodes in patients with operable stage of lung cancer.
Authors: Christoph Frank Dietrich; Jouke Tabe Annema; Paul Clementsen; Xin Wu Cui; Mathias Maximilian Borst; Christian Jenssen Journal: J Thorac Dis Date: 2015-09 Impact factor: 2.895
Authors: Johannes Kirchner; Esther Maria Kirchner; Jan Peter Goltz; Vivian-Wilma Lorenz; Ralph Kickuth Journal: Eur Radiol Date: 2011-04-10 Impact factor: 5.315