Literature DB >> 8873737

Activation of coagulation and fibrinolytic pathways in patients with left ventricular assist devices.

T Spanier1, M Oz, H Levin, A Weinberg, K Stamatis, D Stern, E Rose, A M Schmidt.   

Abstract

Left ventricular assist devices have provided successful supportive therapy for patients awaiting cardiac transplantation for extended periods of time. Although thromboembolic events have complicated support with these devices, the HeartMate left ventricular assist device developed by Thermo Cardiosystems, Inc., Woburn, Massachusetts, was specifically designed with a textured blood-contacting surface to minimize this risk. Clinical experience with this device has been encouraging, inasmuch as minimal thromboembolic complications have occurred despite the absence of anticoagulation. The coagulation and fibrinolytic pathways in these individuals were investigated to better understand the hematologic status of patients treated with the Thermo Cardiosystems device. Despite apparently normal prothrombin and activated partial thromboplastin times, as well as platelet counts, evidence of significant thrombin generation and fibrinolysis was present. To eliminate underlying cardiac failure as the responsible factor for these abnormalities, we made similar measurements in patients with end-stage heart failure who were not supported by an assist device or anticoagulation. These measurements revealed no evidence of thrombin generation or fibrinolysis. These data demonstrate that patients supported with a left ventricular assist device, while successfully sustained without systemic anticoagulation, nevertheless have evidence of activation of coagulation. These phenomena appear to be related to the presence of the device rather than to the underlying cardiac abnormalities. Although procoagulant and fibrinolytic pathways are apparently balanced in these patients, these data underscore the potential for the development of bleeding or thrombosis in clinically relevant settings.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8873737     DOI: 10.1016/S0022-5223(96)70111-3

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  12 in total

1.  Elevated Angiopoietin-2 Level in Patients With Continuous-Flow Left Ventricular Assist Devices Leads to Altered Angiogenesis and Is Associated With Higher Nonsurgical Bleeding.

Authors:  Corey E Tabit; Phetcharat Chen; Gene H Kim; Savitri E Fedson; Gabriel Sayer; Mitchell J Coplan; Valluvan Jeevanandam; Nir Uriel; James K Liao
Journal:  Circulation       Date:  2016-06-28       Impact factor: 29.690

Review 2.  Mechanical circulatory support.

Authors:  Deborah J Kozik; Mark D Plunkett
Journal:  Organogenesis       Date:  2011-01-01       Impact factor: 2.500

Review 3.  Coagulopathy in Mechanical Circulatory Support: A Fine Balance.

Authors:  Julie L Rosenthal; Randall C Starling
Journal:  Curr Cardiol Rep       Date:  2015-12       Impact factor: 2.931

4.  Hematologic effects of continuous flow left ventricular assist devices.

Authors:  Mark S Slaughter
Journal:  J Cardiovasc Transl Res       Date:  2010-09-11       Impact factor: 4.132

Review 5.  The biological basis of thrombosis and bleeding in patients with ventricular assist devices.

Authors:  Ranjit John; Sangjin Lee
Journal:  J Cardiovasc Transl Res       Date:  2008-10-17       Impact factor: 4.132

6.  Medical and Surgical Management of Left Ventricular Assist Device-Associated Intracranial Hemorrhage.

Authors:  Chinwe Ibeh; David L Tirschwell; Claudius Mahr; Claire J Creutzfeldt
Journal:  J Stroke Cerebrovasc Dis       Date:  2021-08-19       Impact factor: 2.677

7.  Prospective, observational study of antiplatelet and coagulation biomarkers as predictors of thromboembolic events after implantation of ventricular assist devices.

Authors:  Farhan Majeed; Willem J Kop; Robert S Poston; Seeta Kallam; Mandeep R Mehra
Journal:  Nat Clin Pract Cardiovasc Med       Date:  2009-02

Review 8.  Management of allosensitized cardiac transplant candidates.

Authors:  Mauricio Velez; Maryl R Johnson
Journal:  Transplant Rev (Orlando)       Date:  2009-10       Impact factor: 3.943

Review 9.  Perioperative pharmacotherapy in patients with left ventricular assist devices.

Authors:  Nicholas C Dang; Yoshifumi Naka
Journal:  Drugs Aging       Date:  2004       Impact factor: 4.271

10.  Preliminary hemocompatibility assessment of an innovative material for blood contacting surfaces.

Authors:  Martina Todesco; Elena Pontara; Chunyan Cheng; Gino Gerosa; Vittorio Pengo; Andrea Bagno
Journal:  J Mater Sci Mater Med       Date:  2021-07-27       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.