Validation of a telemetry system for long-term measurement of blood pressure.

D Brooks1, R L Horner, L F Kozar, T K Waddell, C L Render, E A Phillipson.   

Abstract

We have used an implanted telemetry system to continuously monitor blood pressure (BP) in three dogs for durations ranging from 28 to 75 wk after implantation. Measurements of BP obtained by telemetry were compared every 3-12 wk, with measurements of BP recorded with a manometer-tipped catheter that was inserted into a femoral artery. Over a wide range of both physiological and pharmacologically manipulated pressures (40-200 mmHg), the values of BP obtained by the two methods were highly correlated (all r > 0.966; all P < or = 0.0001). However, the mean differences between the values obtained by the two systems were different from zero (range +29.6 to -1.5 mmHg; P < or = 0.0001), indicating an offset in the BP values recorded from the implanted system. Furthermore, this offset was dependent on the absolute level of the BP. The findings indicate that, for a period of at least 28 wk and up to 75 wk after implantation, the telemetry system accurately measures acute changes in BP and can reliably measure absolute BP provided that the system is properly validated.

Entities:  

Mesh:

Year:  1996        PMID: 8872674     DOI: 10.1152/jappl.1996.81.2.1012

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  4 in total

1.  Obstructive sleep apnea as a cause of systemic hypertension. Evidence from a canine model.

Authors:  D Brooks; R L Horner; L F Kozar; C L Render-Teixeira; E A Phillipson
Journal:  J Clin Invest       Date:  1997-01-01       Impact factor: 14.808

2.  Comparison of telemetry and high-definition oscillometry for blood pressure measurements in conscious dogs: effects of torcetrapib.

Authors:  Olivier Meyer; Roland Jenni; Andrea Greiter-Wilke; Alexander Breidenbach; Henry H Holzgrefe
Journal:  J Am Assoc Lab Anim Sci       Date:  2010-07       Impact factor: 1.232

3.  Fully Implantable Arterial Blood Glucose Device for Metabolic Research Applications in Rats for Two Months.

Authors:  Robert Brockway; Scott Tiesma; Heather Bogie; Kimberly White; Megan Fine; Libbey O'Farrell; Mervyn Michael; Amy Cox; Tamer Coskun
Journal:  J Diabetes Sci Technol       Date:  2015-05-27

4.  An Universal packaging technique for low-drift implantable pressure sensors.

Authors:  Albert Kim; Charles R Powell; Babak Ziaie
Journal:  Biomed Microdevices       Date:  2016-04       Impact factor: 2.838

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.