Literature DB >> 8872599

Small caliber vascular grafts. Part II: Polyurethanes revisited.

R J Zdrahala1.   

Abstract

Polyurethanes are considered to be one of the most bio- and blood-compatible biomaterials known today. By intelligent utilization of principles governing the structure/property relationship of these polymers, one can generate systems which resemble, in principle, the physical-mechanical behavior of living tissue. Thus, it is not surprising that these materials played a major role in development of small caliber vascular grafts targeted for vascular access, peripheral and coronary artery bypass indications. Numerous technologies, often esoteric in nature, were and are utilized to generate porous, potentially multilayered conduits possessing some or many characteristics of natural blood vessels. Properties such as durability, elasticity, compliance, pulsatility, and propensity for healing became attainable via polyurethanes. Furthermore, additional surface and/or bulk modification via attachments of biologically active species such as anticoagulants, cell proliferation suppressants, anti-infective compounds or biorecognizable groups are possible due to reactive groups which are part of the polyurethane structure. These modifications are designed to control or mediate host acceptance and healing of the graft. Finally, a myriad of practical processing technologies are used to fabricate functional grafts. Among those, casting, electrostatic and wet spinning of fibers and monofilaments, extrusion, dip coating or spraying of mandrels with polymer/additive solutions are often coupled with chemical-potential-difference-driven coagulation and phase inversion leading to grafts feeling and often behaving like natural vessels. Historically, the first polyurethanes utilized were hydrolytically unstable polyester polyurethanes containing hydrolysis-prone polyester polyols as soft segments, followed by hydrolytically stable but oxidation sensitive polyether polyols based polyurethanes. Polyether-based polyurethanes and their clones containing silicone and other modifying polymeric intermediates represented significant progress. Many viable technologies were discovered and developed using polyether-based polyurethanes. Chronic in vivo instability observed on prolonged implantation became, however, a major roadblock. The path led finally to the use of hydrolytically and oxidatively stable polycarbonate polyols as the soft segment to generate biodurable materials with resistance to biodegradation adequate for vascular access or perhaps peripheral graft indications. This biodurability needs to be further increased in order to utilize the full potential of polyurethanes in development of patent small caliber graft. Modification of both the soft and hard segments needs to be considered in order to maximize biodurability of both basic building blocks of the polyurethane. This paper reviews the achievements, discusses trends, and offers the view of the future in this exciting area of material/device combination.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8872599     DOI: 10.1177/088532829601100102

Source DB:  PubMed          Journal:  J Biomater Appl        ISSN: 0885-3282            Impact factor:   2.646


  7 in total

1.  Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents.

Authors:  Susheil Uthamaraj; Brandon J Tefft; Soumen Jana; Ota Hlinomaz; Manju Kalra; Amir Lerman; Dan Dragomir-Daescu; Gurpreet S Sandhu
Journal:  J Vis Exp       Date:  2016-10-26       Impact factor: 1.355

2.  End-point immobilization of heparin on plasma-treated surface of electrospun polycarbonate-urethane vascular graft.

Authors:  Xuefeng Qiu; Benjamin Li-Ping Lee; Xinghai Ning; Niren Murthy; Nianguo Dong; Song Li
Journal:  Acta Biomater       Date:  2017-01-06       Impact factor: 8.947

3.  Studies of polyurethane urea bands for ACL reconstruction.

Authors:  Elisabeth Liljensten; Katrin Gisselfält; Bengt Edberg; Hans Bertilsson; Per Flodin; Anders Nilsson; Anders Lindahl; Lars Peterson
Journal:  J Mater Sci Mater Med       Date:  2002-04       Impact factor: 3.896

Review 4.  Mesenchymal stem cells for vascular regeneration.

Authors:  Ngan F Huang; Song Li
Journal:  Regen Med       Date:  2008-11       Impact factor: 3.806

Review 5.  Generation and Assessment of Functional Biomaterial Scaffolds for Applications in Cardiovascular Tissue Engineering and Regenerative Medicine.

Authors:  Svenja Hinderer; Eva Brauchle; Katja Schenke-Layland
Journal:  Adv Healthc Mater       Date:  2015-03-16       Impact factor: 9.933

6.  Cylindrical Polyurethane Scaffold Fabricated Using the Phase Inversion Method: Influence of Process Parameters on Scaffolds' Morphology and Mechanical Properties.

Authors:  Aleksandra Kuźmińska; Dominika Kwarta; Tomasz Ciach; Beata A Butruk-Raszeja
Journal:  Materials (Basel)       Date:  2021-05-31       Impact factor: 3.623

7.  Progress and challenges in biomaterials used for bone tissue engineering: bioactive glasses and elastomeric composites.

Authors:  Qizhi Chen; Chenghao Zhu; George A Thouas
Journal:  Prog Biomater       Date:  2012-09-26
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.