Literature DB >> 8867679

Lens adherence and postlens tear film changes in closed-eye wear of hydrogel lenses.

A S Bruce1, J C Mainstone.   

Abstract

BACKGROUND: Lens adherence and a reduced postlens tear film circulation have been suggested as factors contributing to some adverse reactions in extended wear of hydrogel contact lenses. In this study, we determined lens fitting and postlens tear film characteristics during closed-eye wear.
METHODS: Twenty subjects wore hydrogel lenses for 3 h of eye closure, followed by 30 min of open-eye wear. Lens movement was measured with a video biomicroscope. Postlens tear film appearances in specular reflection were classified as either amorphous, or as one of four color intensity grades, where a colored appearance was taken as indicative of a depleted postlens tear film.
RESULTS: All subjects showed lens adherence (movement < 0.1 mm) and postlens tear film depletion within 45 min of eye closure. These changes were sustained for the remainder of the closed-eye period, but were reversed within 15 min of eye opening. Lens adherence was associated with colored postlens tear film patterns of any intensity.
CONCLUSION: Closed-eye wear was invariably associated with the onset of lens adherence and postlens tear film depletion. This finding emphasizes the need for adequate lens movement during the open-eye phase of extended wear.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8867679     DOI: 10.1097/00006324-199601000-00005

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  4 in total

1.  Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses.

Authors:  Qi Chen; Jianhua Wang; Aizhu Tao; Meixiao Shen; Shuliang Jiao; Fan Lu
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-11-20       Impact factor: 4.799

2.  The association between mucin balls and corneal infiltrative events during extended contact lens wear.

Authors:  Loretta Szczotka-Flynn; Beth Ann Benetz; Jonathan Lass; Matthew Albright; Beth Gillespie; Jana Kuo; Desmond Fonn; Ajay Sethi; Alfred Rimm
Journal:  Cornea       Date:  2011-05       Impact factor: 2.651

3.  Prolonged increase in tear meniscus height by 3% diquafosol ophthalmic solution in eyes with contact lenses.

Authors:  Yukiko Nagahara; Shizuka Koh; Kohji Nishida; Hitoshi Watanabe
Journal:  Clin Ophthalmol       Date:  2015-06-09

4.  Characterization of Soft Contact Lens Edge Fitting during Daily Wear Using Ultrahigh-Resolution Optical Coherence Tomography.

Authors:  Lele Cui; Sisi Chen; Weihe Zhou; Kaixuan Sheng; Lei Zhang; Meixiao Shen; Ming Li
Journal:  J Ophthalmol       Date:  2018-05-13       Impact factor: 1.909

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.