Literature DB >> 8867677

Spoilation and clinical performance of monthly vs. three monthly Group II disposable contact lenses.

L Jones1, V Franklin, K Evans, R Sariri, B Tighe.   

Abstract

Twelve subjects were fitted with a high water content, nonionic contact lens (Pilkington Barnes-Hind "Precision UV"), which was either replaced every month for 3 months or worn for 3 consecutive months before replacement occurred. Visual quality, high and low contrast acuity, and comfort were unaltered with either replacement schedule, but overall satisfaction was significantly greater with the shorter replacement schedule (p = 0.04). Front surface wettability revealed a large amount of intersubject variability and was reduced at the 3-month visit with the longer replacement period lenses (p = 0.003). Visible deposits also increased with longer replacement times (p < 0.05). Laboratory-based analytical results showed that both gross lipid and gross extractable protein significantly increased in the 3-month lenses compared with the 1-month lenses, with 44% less lipid accumulation and 60% less protein deposition occurring with the shorter replacement time. The results support the replacement of high water content lenses on a monthly basis.

Entities:  

Mesh:

Year:  1996        PMID: 8867677     DOI: 10.1097/00006324-199601000-00003

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  5 in total

Review 1.  The international workshop on meibomian gland dysfunction: report of the subcommittee on tear film lipids and lipid-protein interactions in health and disease.

Authors:  Kari B Green-Church; Igor Butovich; Mark Willcox; Douglas Borchman; Friedrich Paulsen; Stefano Barabino; Ben J Glasgow
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-03-30       Impact factor: 4.799

2.  Quantification of individual proteins in silicone hydrogel contact lens deposits.

Authors:  Negar Babaei Omali; Zhenjun Zhao; Hua Zhu; Daniel Tilia; Mark D P Willcox
Journal:  Mol Vis       Date:  2013-02-18       Impact factor: 2.367

3.  Proteomic analysis of protein deposits on worn daily wear silicone hydrogel contact lenses.

Authors:  Zhenjun Zhao; Xiaojia Wei; Yulina Aliwarga; Nicole A Carnt; Qian Garrett; Mark D P Willcox
Journal:  Mol Vis       Date:  2008-11-07       Impact factor: 2.367

4.  Mass spectrometry-based proteomic analyses of contact lens deposition.

Authors:  Kari B Green-Church; Jason J Nichols
Journal:  Mol Vis       Date:  2008-02-08       Impact factor: 2.367

5.  Evaluation of surface water characteristics of novel daily disposable contact lens materials, using refractive index shifts after wear.

Authors:  Jeffery Schafer; Robert Steffen; William Reindel; Joseph Chinn
Journal:  Clin Ophthalmol       Date:  2015-10-22
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.