Literature DB >> 8865764

Exact mass measurement of polar organic molecules at low resolution using electrospray ionization and a quadrupole mass spectrometer.

A N Tyler1, E Clayton, B N Green.   

Abstract

Hitherto, exact mass measurement experiments have usually been performed using high-resolution mass spectrometry. However, under the right circumstances, measurements with comparable accuracy may be made at low resolution. Here we demonstrate the use of a low-resolution single-quadrupole mass spectrometer to accurately mass measure organic samples analyzed by electrospray ionization, using a variety of glycol polymers for internal calibration. Results are presented from 11 samples which yield molecular signals in the m/z range 190-750, including data for positive, negative, and multiply-charged sample and reference ions. Replicate determinations of the masses of 12 ions gave values within 4.5 ppm (1.1 millimass units, mmu) of their calculated values, with standard deviations no larger than 3 ppm (1.7 mmu). From a total of 88 individual 1 min measurements, 83 were within 5 ppm, and 87 within 2 mmu of the theoretical mass. The accuracy, precision, and sensitivity shown here are comparable to those achievable using high-resolution mass spectrometers, with the added benefits of simpler instrumentation and analytical technique afforded by the quadrupole mass analyzer.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8865764     DOI: 10.1021/ac9603791

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Mass spectral fragmentation reactions of a therapeutic 4-azasteroid and related compounds.

Authors:  D J Burinsky; J D Williams; A D Thornquest; S L Sides
Journal:  J Am Soc Mass Spectrom       Date:  2001-04       Impact factor: 3.109

Review 2.  Electrospray and tandem mass spectrometry in biochemistry.

Authors:  W J Griffiths; A P Jonsson; S Liu; D K Rai; Y Wang
Journal:  Biochem J       Date:  2001-05-01       Impact factor: 3.857

3.  Intercomparison study on accurate mass measurement of small molecules in mass spectrometry.

Authors:  Anthony W T Bristow; Kenneth S Webb
Journal:  J Am Soc Mass Spectrom       Date:  2003-10       Impact factor: 3.109

4.  Mass spectral fragmentation reactions of angiotensin-converting enzyme (ACE) inhibitors.

Authors:  David J Burinsky; Scott L Sides
Journal:  J Am Soc Mass Spectrom       Date:  2004-09       Impact factor: 3.109

Review 5.  Accurate mass measurements in proteomics.

Authors:  Tao Liu; Mikhail E Belov; Navdeep Jaitly; Wei-Jun Qian; Richard D Smith
Journal:  Chem Rev       Date:  2007-07-25       Impact factor: 60.622

6.  Electrospray mass spectrometry for the direct accurate mass measurement of ligands in complex with the retinoid X receptor alpha ligand binding domain.

Authors:  Johan Lengqvist; Gunvor Alvélius; Hans Jörnvall; Jan Sjövall; Thomas Perlmann; William J Griffiths
Journal:  J Am Soc Mass Spectrom       Date:  2005-10       Impact factor: 3.109

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.