Literature DB >> 8857352

Nonlinear viscoelasticity and the thrombelastograph: 1. Studies on bovine plasma clots.

W R Burghardt1, T K Goldstick, J Leneschmidt, K Kempka.   

Abstract

To study the possible role of nonlinear viscoelastic effects in the thrombelastograph (TEG), clotting of bovine plasma was studied by both thrombelastography and with a controlled strain rheometer. Clot rheology is dominated by elastic effects at frequencies of interest. There is a well-defined regime of linear elasticity for strains less than around 2%, while at larger strains the clots show significant strain hardening. Oscillatory shear applied during clotting has little effect on the resulting clot provided that the strain is less than 2%, but leads to substantial weakening of clots formed at larger strains. The TEG operates within the regime of nonlinear elasticity, significantly obscuring the interpretation of TEG amplitude in terms of an elastic modulus. Comparing the results of standard TEG experiments with those conducted with a modified TEG, having no oscillation during clotting, shows that deformation during standard thrombelastography leads to weaker clots than are produced under quiescent conditions.

Entities:  

Mesh:

Year:  1995        PMID: 8857352     DOI: 10.1016/0006-355X(95)00041-7

Source DB:  PubMed          Journal:  Biorheology        ISSN: 0006-355X            Impact factor:   1.875


  11 in total

1.  Towards the limit of quantifying low-amplitude strains on bone and in coagulum around immediately loaded oral implants in extraction sockets.

Authors:  Murat Cavit Cehreli; Ayhan Comert; Murat Akkocaoglu; Ibrahim Tekdemir; Kivanc Akca
Journal:  Med Biol Eng Comput       Date:  2006-03       Impact factor: 2.602

Review 2.  The pathophysiology, diagnosis and treatment of the acute coagulopathy of trauma and shock: a literature review.

Authors:  J Kaczynski; M Wilczynska; L Fligelstone; J Hilton
Journal:  Eur J Trauma Emerg Surg       Date:  2013-12-12       Impact factor: 3.693

3.  Effect of fibrin polymerzation on flow properties of coagulating blood.

Authors:  P Riha; F Liao; J F Stoltz
Journal:  J Biol Phys       Date:  1997-06       Impact factor: 1.365

4.  Adaptive force sonorheometry for assessment of whole blood coagulation.

Authors:  F William Mauldin; Francesco Viola; Theresa C Hamer; Eman M Ahmed; Shawna B Crawford; Doris M Haverstick; Michael B Lawrence; William F Walker
Journal:  Clin Chim Acta       Date:  2010-01-22       Impact factor: 3.786

5.  A novel ultrasound-based method to evaluate hemostatic function of whole blood.

Authors:  Francesco Viola; F William Mauldin; Xiefan Lin-Schmidt; Doris M Haverstick; Michael B Lawrence; William F Walker
Journal:  Clin Chim Acta       Date:  2009-10-25       Impact factor: 3.786

6.  A Novel Device for the Evaluation of Hemostatic Function in Critical Care Settings.

Authors:  Elisa A Ferrante; Kiev R Blasier; Thomas B Givens; Cynthia A Lloyd; Timothy J Fischer; Francesco Viola
Journal:  Anesth Analg       Date:  2016-12       Impact factor: 5.108

7.  Integration of acoustic radiation force and optical imaging for blood plasma clot stiffness measurement.

Authors:  Caroline W Wang; Matthew J Perez; Brian P Helmke; Francesco Viola; Michael B Lawrence
Journal:  PLoS One       Date:  2015-06-04       Impact factor: 3.240

8.  A constitutive model for developing blood clots with various compositions and their nonlinear viscoelastic behavior.

Authors:  Thomas H S van Kempen; Wouter P Donders; Frans N van de Vosse; Gerrit W M Peters
Journal:  Biomech Model Mechanobiol       Date:  2015-06-05

9.  Optical sensing of anticoagulation status: Towards point-of-care coagulation testing.

Authors:  Diane M Tshikudi; Markandey M Tripathi; Zeinab Hajjarian; Elizabeth M Van Cott; Seemantini K Nadkarni
Journal:  PLoS One       Date:  2017-08-03       Impact factor: 3.240

Review 10.  Assessing the Methodology for Calculating Platelet Contribution to Clot Strength (Platelet Component) in Thromboelastometry and Thrombelastography.

Authors:  Cristina Solomon; Marco Ranucci; Gerald Hochleitner; Herbert Schöchl; Christoph J Schlimp
Journal:  Anesth Analg       Date:  2015-10       Impact factor: 6.627

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.