Literature DB >> 8849972

Cardiac artifacts in magnetoencephalogram.

V Jousmäki1, R Hari.   

Abstract

We studied cardiac contamination of magnetoencephalographic signals in eight healthy volunteers. The signals were recorded in a magnetically shielded room while the subject was sitting under a whole-scalp neuromagnetometer and were averaged time-locked to the R wave of the electrocardiogram. The maximum amplitude of the cardiac artifact varied between the subjects and was on average 130 fT/cm. The number of significantly contaminated channels was higher over the left than the right hemisphere. The electric and magnetic signals varied over time in the same way, implying that the artifacts are generated by cardiac currents, without any significant contribution from blood-flow-related pulsations or body movements. These artifacts may have a considerable effect on unaveraged data, i.e., recordings of spontaneous brain activity, and thus should be taken into account in the analysis.

Mesh:

Year:  1996        PMID: 8849972     DOI: 10.1097/00004691-199603000-00008

Source DB:  PubMed          Journal:  J Clin Neurophysiol        ISSN: 0736-0258            Impact factor:   2.177


  9 in total

1.  Signal-space projection method for separating MEG or EEG into components.

Authors:  M A Uusitalo; R J Ilmoniemi
Journal:  Med Biol Eng Comput       Date:  1997-03       Impact factor: 2.602

2.  Removing Cardiac Artefacts in Magnetoencephalography with Resampled Moving Average Subtraction.

Authors:  Limin Sun; Seppo P Ahlfors; Hermann Hinrichs
Journal:  Brain Topogr       Date:  2016-08-08       Impact factor: 3.020

3.  Facilitating neuronal connectivity analysis of evoked responses by exposing local activity with principal component analysis preprocessing: simulation of evoked MEG.

Authors:  Lin Gao; Tongsheng Zhang; Jue Wang; Julia Stephen
Journal:  Brain Topogr       Date:  2012-08-24       Impact factor: 3.020

4.  MEG Insight into the Spectral Dynamics Underlying Steady Isometric Muscle Contraction.

Authors:  Mathieu Bourguignon; Harri Piitulainen; Eero Smeds; Guangyu Zhou; Veikko Jousmäki; Riitta Hari
Journal:  J Neurosci       Date:  2017-09-26       Impact factor: 6.167

5.  Improving Localization Accuracy of Neural Sources by Pre-processing: Demonstration With Infant MEG Data.

Authors:  Maggie D Clarke; Eric Larson; Erica R Peterson; Daniel R McCloy; Alexis N Bosseler; Samu Taulu
Journal:  Front Neurol       Date:  2022-03-23       Impact factor: 4.003

6.  Splitting of the magnetic encephalogram into «brain» and «non-brain» physiological signals based on the joint analysis of frequency-pattern functional tomograms and magnetic resonance images.

Authors:  Rodolfo R Llinás; Stanislav Rykunov; Kerry D Walton; Anna Boyko; Mikhail Ustinin
Journal:  Front Neural Circuits       Date:  2022-08-26       Impact factor: 3.342

Review 7.  Magnetoencephalography: fundamentals and established and emerging clinical applications in radiology.

Authors:  Sven Braeutigam
Journal:  ISRN Radiol       Date:  2013-08-12

8.  Multimodal brain imaging with magnetoencephalography: A method for measuring blood pressure and cardiorespiratory oscillations.

Authors:  Teemu Myllylä; Norman Zacharias; Vesa Korhonen; Aleksandra Zienkiewicz; Hermann Hinrichs; Vesa Kiviniemi; Martin Walter
Journal:  Sci Rep       Date:  2017-03-14       Impact factor: 4.379

9.  A New Recognition Method for the Auditory Evoked Magnetic Fields.

Authors:  Yulong Feng; Wei Xiao; Teng Wu; Jianwei Zhang; Jing Xiang; Hong Guo
Journal:  Comput Intell Neurosci       Date:  2021-02-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.