Literature DB >> 8849842

Periodontal probe precision using 4 different periodontal probes.

L Mayfield1, G Bratthall, R Attström.   

Abstract

The aim of this study was to compare the relative intra- and inter-examiner reproducibility of 4 different periodontal probes. (1) The Hu- Friedy LL 20 Probe, a manual probe. (2) The Vivacare TPS Probe, a plastic manual probe with a standardised pressure of 0.20 N. (3) The Vine Valley Probe, an electronic probe using a standardised pressure of 0.25 N. 4. The Peri Probe Comp, a computerised electronic probe with a controlled pressure of 0.45 N in 2 mm pockets to 0.25 N in 13 mm pockets. Duplicate probing measurements were taken by 2 examiners in 10 patients on 3 index teeth, 1 molar, 1 premolar and 1 incisor at 6 sites per tooth. Teeth were selected to incorporate both shallow (< 5 mm) and deeper (> or = 5 mm) periodontal sites. The order of probes and examiners were changed in a systematic manner and measurements were repeated 1 week later to avoid bias due to examiner memory. Results show that the manual probe had the lowest degree of variation, with a correlation coefficient of 0.83. The manual and Peri Probe Comp frequently recorded deeper probing pocket depths compared to the TPS and Vine Valley probes. The results may have been influenced by the lack of familiarity with the automated probes.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8849842     DOI: 10.1111/j.1600-051x.1996.tb00538.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  6 in total

1.  Photoacoustic Imaging for Noninvasive Periodontal Probing Depth Measurements.

Authors:  C Y Lin; F Chen; A Hariri; C J Chen; P Wilder-Smith; T Takesh; J V Jokerst
Journal:  J Dent Res       Date:  2017-09-07       Impact factor: 6.116

2.  Obstructive sleep apnoea and periodontitis: a novel association?

Authors:  Kogulan Gunaratnam; Barbara Taylor; Bradley Curtis; Peter Cistulli
Journal:  Sleep Breath       Date:  2009-02-06       Impact factor: 2.816

3.  Assessment of Intra- and Inter-examiner Reproducibility of Probing Depth Measurements with a Manual Periodontal Probe.

Authors:  Ardeshir Lafzi; Adileh Shir Mohammadi; Amir Eskandari; Sohrab Pourkhamneh
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2007-06-10

4.  Comparisons of the diagnostic accuracies of optical coherence tomography, micro-computed tomography, and histology in periodontal disease: an ex vivo study.

Authors:  Jin-Young Park; Jung-Ho Chung; Jung-Seok Lee; Hee-Jin Kim; Seong-Ho Choi; Ui-Won Jung
Journal:  J Periodontal Implant Sci       Date:  2017-02-28       Impact factor: 2.614

5.  Comparative evaluation of probing depth and clinical attachment level using a manual probe and Florida probe.

Authors:  Amandeep Kour; Ashish Kumar; Komal Puri; Manish Khatri; Mansi Bansal; Geeti Gupta
Journal:  J Indian Soc Periodontol       Date:  2016 May-Jun

6.  Clinical Evaluation of a New Electronic Periodontal Probe: A Randomized Controlled Clinical Trial.

Authors:  Oliver Laugisch; Thorsten M Auschill; Christian Heumann; Anton Sculean; Nicole B Arweiler
Journal:  Diagnostics (Basel)       Date:  2021-12-25
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.