Power Doppler ultrasound evaluation of the shear rate and shear stress dependences of red blood cell aggregation.

G Cloutier1, Z Qin, L G Durand, B G Teh.   

Abstract

The use of power Doppler ultrasound at 10 MHz is evaluated as a method to study the shear rate and the shear stress dependences of red blood cell aggregation. This evaluation was based on six in vitro experiments conducted in a 1.27-cm diameter tube under steady flow conditions. Porcine whole blood was circulated in the flow model at flow rates ranging between 125 to 1500 ml/min (mean shear rate across the tube ranging between 6 and 74 s-1). For each flow condition, the variation of the Doppler power across the tube and the velocity profile were measured by moving the Doppler sample volume across the tube diameter. For each radial position, the shear rate within the Doppler sample volume was also determined by considering the radial power pattern of the ultrasound beam. To estimate the shear stress within the Doppler sample volume, the apparent viscosity of blood samples withdrawn from the flow model was measured for each experiment. The variation of the Doppler power as a function of the shear rate within the sample volume showed a rapid reduction of the power between 1 and 5 s-1, a transition region between 5 and 10 s-1, and a very slow reduction beyond 10 s-1. Little variation of the Doppler power was measured for shear stress higher than 2 dyn/cm2. The maximum Doppler power for all flow rates was usually found near the center of the tube. Based on the ultrasonic scattering models, which predict that the Doppler power is related to the volume square of the scatterers, the method described in the present study showed a very high sensitivity to the presence of red blood cell aggregation for shear rates below 10 s-1.

Mesh:

Substances:

Year:  1996        PMID: 8849457     DOI: 10.1109/10.488792

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

1.  In vivo vascular wall shear rate and circumferential strain of renal disease patients.

Authors:  Dae Woo Park; Grant H Kruger; Jonathan M Rubin; James Hamilton; Paul Gottschalk; Robert E Dodde; Albert J Shih; William F Weitzel
Journal:  Ultrasound Med Biol       Date:  2012-12-01       Impact factor: 2.998

2.  In vivo venous assessment of red blood cell aggregate sizes in diabetic patients with a quantitative cellular ultrasound imaging method: proof of concept.

Authors:  Julien Tripette; Linh-Chi Nguyen; Louise Allard; Pierre Robillard; Gilles Soulez; Guy Cloutier
Journal:  PLoS One       Date:  2015-04-23       Impact factor: 3.240

3.  Bio-Impedance Sensor for Real-Time Artery Diameter Waveform Assessment.

Authors:  Mugeb Al-Harosh; Marat Yangirov; Dmitry Kolesnikov; Sergey Shchukin
Journal:  Sensors (Basel)       Date:  2021-12-17       Impact factor: 3.576

4.  Contrast Agent-Free Assessment of Blood Flow and Wall Shear Stress in the Rabbit Aorta using Ultrasound Image Velocimetry.

Authors:  Kai Riemer; Ethan M Rowland; Jacob Broughton-Venner; Chee Hau Leow; Mengxing Tang; P D Weinberg
Journal:  Ultrasound Med Biol       Date:  2021-12-05       Impact factor: 2.998

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.