P Dijkhuizen, A Buursma, A M Gerding, W G Zijlstra.
Abstract
The spectrophotometry properties of sulfhaemoglobin (SHb) and some derivatives were investigated using an improved technique for measuring the SHb fraction induced in human blood samples. The millimolar extinction coefficient of SHb at lambda = 620 nm was found to be 20.8 (S.D. 1.48; S.E. = 0.44; n = 11). In addition it was demonstrated that the spectral changes occurring in SHb containing haemoglobin solutions upon the addition of KCN, K3Fe(CN)6 and K3Fe(CN)6 +KCN invalidate the KCN addition method for the determination of haemiglobin. The influence of clinically occurring SHb fractions on the internationally standarized total haemoglobin determination were shown to be insignificant.Entities:
Mesh:
Substances:
Year: 1977 PMID: 884871 DOI: 10.1016/0009-8981(77)90081-x
Source DB: PubMed Journal: Clin Chim Acta ISSN: 0009-8981 Impact factor: 3.786