Salvage of infected ICDs: management without removal.

J H Lee1, A S Geha, N M Rattehalli, B L Cmolik, N J Johnson, L A Biblo, M D Carlson, A L Waldo.   

Abstract

During the 7-year period from August 1986 to December 1993, 242 patients with malignant ventricular arrhythmias underwent 242 ICD implantations and 50 subcutaneous generator changes. Wound infections developed in 5 patients (1.7%): in 3 cases, after primary implantation (3/242 [1.2%]); and in 2 following a generator change (2/50 [4.0%]). This difference was not statistically significant. Infection developed at the generator pocket and became clinically manifest between 6 weeks and 40 months, postoperatively. Our treatment approach with the first patient consisted of simple debridement of the pocket and reimplantation of the existing generator. This led to recurrence, and the generator was safely explanted. In the remaining four patients, our approach has been that of local treatment, with wide debridement of the pocket, and placement of a closed irrigation system with continuous irrigation with a bacitracin, polymyxin, neomycin solution, and culture-specific antibiotic therapy. We have successfully controlled the infection and salvaged the generator with this approach in all four patients, who are all alive and well at a mean follow-up of 25.0 +/- 17.3 months with no recurrence. The good results obtained in these patients suggest that the concept of total explanation of the infected ICD should be reassessed.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8848391     DOI: 10.1111/j.1540-8159.1996.tb06514.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

1.  Local symptoms at the site of pacemaker implantation indicate latent systemic infection.

Authors:  D Klug; F Wallet; D Lacroix; C Marquié; C Kouakam; S Kacet; R Courcol
Journal:  Heart       Date:  2004-08       Impact factor: 5.994

Review 2.  Endovascular extraction techniques: Part 2: Complications and indications.

Authors:  F A Bracke; A Meijer; B van Gelder
Journal:  Neth Heart J       Date:  2001-05       Impact factor: 2.380

3.  An effective technique for salvage of cardiac-related devices.

Authors:  Erin K Knepp; Karan Chopra; Hamid R Zahiri; Luther H Holton Iii; Devinder P Singh
Journal:  Eplasty       Date:  2012-01-24

4.  Safe and Simplified Salvage Technique for Exposed Implantable Cardiac Electronic Devices under Local Anesthesia.

Authors:  Chang Young Jung; Tae Gon Kim; Sung-Eun Kim; Kyu-Jin Chung; Jun Ho Lee; Yong-Ha Kim
Journal:  Arch Plast Surg       Date:  2017-01-20

5.  Salvage of focally infected implantable cardioverter-defibrillator system by in situ hardware sterilization.

Authors:  Robert D Schaller; Joshua M Cooper
Journal:  HeartRhythm Case Rep       Date:  2017-07-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.