Comparison of gold versus platinum electrodes on myocardial lesion size using radiofrequency energy.

W N Simmons1, S Mackey, D S He, F I Marcus.   

Abstract

During radiofrequency (RF) catheter ablation of arrhythmias, temperatures that approach 100 degrees C cause a coagulum to form on the ablation electrode that results in an increase in electrical impedance and prevents further energy delivery. Since gold has nearly four times the thermal conductivity as platinum, the metal commonly used, it was postulated that gold tip electrodes could deliver more power and produce deeper lesions because of its greater heat dissipation from the electrode-tissue interface to the circulating blood. To test this hypothesis, RF energy was applied to fresh bovine ventricular myocardium using 6 French catheters with 2-mm long distal electrodes made from gold or platinum. Similar studies were also conducted using 7 French catheters with 4-mm long distal electrodes. Maximum lesion depth was defined as that produced with the level of energy just below that causing an impedance rise. A maximum lesion depth of 6.2 +/- 0.7 mm (mean +/- SD) was obtained with the gold 2-mm electrode and 4.7 +/- 0.5 mm with the platinum electrode (P = 0.003). The 4-mm gold electrode produced a maximum lesion depth of 7.2 +/- 1.4 mm, while a catheter with a 4-mm platinum electrode caused a maximum lesion depth of 5.8 +/- 0.7 mm (P = 0.05). We conclude that deeper lesions should be able to be made when RF energy is delivered to a gold rather than platinum tip electrode.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8848386     DOI: 10.1111/j.1540-8159.1996.tb06509.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

1.  Ring electrode for radio-frequency heating of the cornea: modelling and in vitro experiments.

Authors:  E J Berjano; J Saiz; J L Alió; J M Ferrero
Journal:  Med Biol Eng Comput       Date:  2003-11       Impact factor: 2.602

Review 2.  Comparison of the Efficacy of PVAC® and nMARQ for paroxysmal atrial fibrillation.

Authors:  Avishag Laish-Farkash; Mahmoud Suleiman
Journal:  J Atr Fibrillation       Date:  2017-04-30

3.  An optimized approach for right atrial flutter ablation: a post hoc analysis of the AURUM 8 study.

Authors:  Thorsten Lewalter; Christian Weiss; Christian Mewis; Werner Jung; Wilhelm Haverkamp; Jochen Proff; Wolfgang Bauer
Journal:  J Interv Card Electrophysiol       Date:  2016-11-05       Impact factor: 1.900

4.  Noninvasive three-dimensional cardiac activation imaging from body surface potential maps: a computational and experimental study on a rabbit model.

Authors:  Chengzong Han; Zhongming Liu; Xin Zhang; Steven Pogwizd; Bin He
Journal:  IEEE Trans Med Imaging       Date:  2008-11       Impact factor: 10.048

5.  Research of electrosurgical ablation with antiadhesive functionalization on thermal and histopathological effects of brain tissues in vivo.

Authors:  Wen-Tien Hsiao; Chun-Ming Kung; Jan-Show Chu; Keng-Liang Ou; Pei-Wen Peng
Journal:  Biomed Res Int       Date:  2014-05-22       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.