Literature DB >> 8846469

Postmortem evaluation of four randomly selected automated biopsy devices for transthoracic lung biopsy.

H J Wagner1, P Barth, C Schade-Brittinger, S Plein, K J Klose.   

Abstract

PURPOSE: To evaluate four automated devices to achieve transthoracic lung biopsy.
METHODS: Transthoracic lung biopsy specimens were obtained randomly from 21 human cadavers with unsuspicious lungs using Biopty (18- and 20-gauge), BIP (18 and 20-gauge), ASAP (18 gauge), and Autovac (18- and 20-gauge) devices. A total of 63 biopsies were carried out with each device and each needle diameter. The same devices and needles were then used randomly for biopsy of peripheral lung metastases. Specimens obtained during both parts of the study were analyzed for the area of tissue on the histologic section, adequacy of tissue for diagnosis, tissue preservation, and crush artifact. The examining pathologist was kept unaware of which procedure was used to obtain the specimens and the cadavers' clinical history.
RESULTS: The Biopty 18-gauge device performed statistically better than any other of the evaluated systems for biopsy of normal lung parenchyma (p < 0.05). For biopsy of lung metastases, the differences between the devices and needle diameters were less, although the Biopty 18-gauge device performed better than the Autovac 18-gauge, BIP 18-gauge, and all 20-gauge devices for the area of tissue on the histologic section (p < 0.05). The results of the full-cut Autovac biopsy system were remarkable because of the large number of biopsies during which no tissue was obtained.
CONCLUSION: Automated biopsy devices can obtain high quality lung specimens sufficient for definite histopathologic diagnosis. However, additional clinical studies on the use of automated biopsy devices for lung biopsy are mandatory.

Entities:  

Mesh:

Year:  1995        PMID: 8846469     DOI: 10.1007/bf00203680

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  16 in total

1.  Percutaneous pediatric renal biopsy: use of the biopsy gun.

Authors:  R B Poster; D B Jones; B A Spirt
Journal:  Radiology       Date:  1990-09       Impact factor: 11.105

2.  Image-directed percutaneous biopsies with a biopsy gun.

Authors:  S H Parker; K D Hopper; W F Yakes; M D Gibson; J L Ownbey; T E Carter
Journal:  Radiology       Date:  1989-06       Impact factor: 11.105

3.  Automated biopsy devices: significance and safety.

Authors:  M E Bernardino
Journal:  Radiology       Date:  1990-09       Impact factor: 11.105

Review 4.  Percutaneous transthoracic needle biopsy.

Authors:  J L Westcott
Journal:  Radiology       Date:  1988-12       Impact factor: 11.105

5.  Renal biopsy: in vitro and in vivo comparison of a new automatic biopsy device and conventional biopsy systems. Work in progress.

Authors:  P Pokieser; R Kain; T Helbich; R Mallek; R M Walter; D Tscholakoff; G H Mostbeck
Journal:  Radiology       Date:  1993-02       Impact factor: 11.105

6.  Biopsy needle characteristics assessed in the laboratory.

Authors:  J G Andriole; J R Haaga; R B Adams; C Nunez
Journal:  Radiology       Date:  1983-09       Impact factor: 11.105

7.  Percutaneous needle biopsy. A new technique.

Authors:  P G Lindgren
Journal:  Acta Radiol Diagn (Stockh)       Date:  1982

8.  Efficacy of automated biopsy guns versus conventional biopsy needles in the pygmy pig.

Authors:  K D Hopper; D E Baird; V V Reddy; J R Landis; S H Parker; H N Tyler; J L Ownbey; M A McCauslin; W F Yakes; F W Sabatelli
Journal:  Radiology       Date:  1990-09       Impact factor: 11.105

9.  CT-guided cutting-needle biopsies of selected chest lesions.

Authors:  C H Goralnik; D M O'Connell; S J el Yousef; J R Haaga
Journal:  AJR Am J Roentgenol       Date:  1988-11       Impact factor: 3.959

10.  Value of having a cytopathologist present during percutaneous fine-needle aspiration biopsy of lung: report of 55 cancer patients and metaanalysis of the literature.

Authors:  J H Austin; M B Cohen
Journal:  AJR Am J Roentgenol       Date:  1993-01       Impact factor: 3.959

View more
  2 in total

1.  Comparison of fully automated and semi-automated biopsy needles for lung biopsy under CT fluoroscopic guidance.

Authors:  R Yoshimatsu; T Yamagami; O Tanaka; H Miura; T Tanaka; T Suzuki; T Nishimura
Journal:  Br J Radiol       Date:  2011-08-09       Impact factor: 3.039

2.  Accuracy of CT-guided transthoracic needle biopsy of lung lesions: factors affecting diagnostic yield.

Authors:  A M Priola; S M Priola; A Cataldi; L Errico; M Di Franco; P Campisi; L Molinaro; V Marci; S Novello; C Fava
Journal:  Radiol Med       Date:  2007-12-13       Impact factor: 3.469

  2 in total