Literature DB >> 8841862

A comparison of the endobronchial segment of modern left-sided double-lumen tubes in anesthesia for bilateral sequential lung transplantation.

L M Watterson1, G A Harrison.   

Abstract

OBJECTIVE: To compare a range of currently available left-sided double-lumen endotracheal tubes (DLTs) in order to demonstrate differences among them with respect to the length of the endobronchial segment. It is proposed that a tube with a short endobronchial segment is better suited to anesthesia under the conditions imposed by double sequential lung transplantation.
SETTING: A university hospital with a large heart and lung transplant unit. PARTICIPANTS: The DLTs included in the study were Sher-I-Bronch (Sheridan of Kendall Australia, North Ryde, Sydney, Australia); BronchoCath and BronchoCath II (Mallinckrodt Medical, St Louis, MO); Rüsch single use (Rüsch, Wailbilngen, Germany); Portex single use (Portex, Keen, NH); and Phoenix single-use Robertshaw (Promedica, Preston, Lancashire, UK).
MEASUREMENTS AND MAIN RESULTS: The endobronchial segment was measured as the distance from the point of inflation of the bronchial cuff to the tip of the tube. This distance was measured for each manufactured brand in a range of tubes and the mean obtained. The DLTs were compared to assess variability within the brand, and the influence of size on the endobronchial segment. All brands were then compared. Variability within brands is consistent with manufacturer's specified range of +/- 1 to 3 mm. The endobronchial segment increases with size for Rusch and Phoenix DLTs as a design feature. The average lengths of the endobronchial segments are Rusch 23 +/- 2 mm (sizes 35/37) and 25 +/- 2 mm (sizes 39/41); Mallinckrodt 30 +/- 3 mm (BronchoCath) and 31 +/- 3 mm (BronchoCath II); Portex 35 +/- 2 mm; Sheridan 35 +/- 2 mm; Phoenix 47 mm (small), 52 mm (medium), and 56 mm (large).
CONCLUSIONS: There exists marked variability in the length of the endobronchial segment of left-sided double-lumen tubes currently available. These differences may be significant in anesthesia for bilateral sequential lung transplantation.

Entities:  

Mesh:

Year:  1996        PMID: 8841862     DOI: 10.1016/s1053-0770(96)80132-7

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  2 in total

1.  Comparisons of the segments of left-sided double-lumen tracheobronchial tubes as industrial products.

Authors:  Zen'ichiro Wajima; Toshiya Shiga; Kazuyuki Imanaga
Journal:  BMC Anesthesiol       Date:  2022-06-08       Impact factor: 2.376

2.  Dimensional Variations of Left-Sided Double-Lumen Endobronchial Tubes.

Authors:  Niels Hegland; Sebastian Schnitzler; Jan Ellensohn; Marc P Steurer; Markus Weiss; Alexander Dullenkopf
Journal:  Anesthesiol Res Pract       Date:  2019-09-24
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.