Use of continuous blood volume monitoring to detect inadequately high dry weight.

F Lopot1, P Kotyk, J Bláha, J Forejt.   

Abstract

A continuous blood volume monitoring (CBVM) device (Inline Diagnostics, Riverdale, USA) was used to study response to prescribed ultrafiltration during haemodialysis (HD) in 66 stabilised HD patients. Fifty percent of patients showed the expected linear decrease in BV right from the beginning of HD (group 1), 32% exhibited no decrease at all (group 2), while eighteen percent formed the transient group 3 which showed a plateau of varying length after which a decrease occurred. The correct setting of dry weight was verified through evaluation of the ratio of extracellular fluid volume to total body water (VEC/TBW) in 26 patients by means of whole body multifrequency impedometry MFI (Xitron Tech., San Diego, USA) and through measurement of the Vena Cava Inferior diameter (VCID) pre and post HD (in 6 and 5 patients from groups 1 and 3 and from group 2, respectively). The mean VEC/TBW in groups 1 and 3 was 0.56 pre and 0.51 post HD as compared to 0.583 and 0.551 in group 2. VCID decreased on average by 14.1% in groups 1 and 3 but remained stable in group 2. Both findings thus confirmed inadequately high estimation of dry weight. Since CBVM is extremely easy to perform it can be used as a method of choice in detecting inadequately high prescribed dry weight. The status of the cardiovascular system must always be considered before final judgement is made.

Entities:  

Mesh:

Year:  1996        PMID: 8841855

Source DB:  PubMed          Journal:  Int J Artif Organs        ISSN: 0391-3988            Impact factor:   1.595


  9 in total

1.  Pulmonary congestion in hemodialysis: an old chestnut worth screening for?

Authors:  Austin G Stack; Liam F Casserly
Journal:  Clin J Am Soc Nephrol       Date:  2013-07-11       Impact factor: 8.237

2.  Hypervolemia is associated with increased mortality among hemodialysis patients.

Authors:  Rajiv Agarwal
Journal:  Hypertension       Date:  2010-07-12       Impact factor: 10.190

3.  Determinants and short-term reproducibility of relative plasma volume slopes during hemodialysis.

Authors:  Sanjiv Anand; Arjun D Sinha; Rajiv Agarwal
Journal:  Clin J Am Soc Nephrol       Date:  2012-09-20       Impact factor: 8.237

Review 4.  Volume Balance and Intradialytic Ultrafiltration Rate in the Hemodialysis Patient.

Authors:  Jason A Chou; Kamyar Kalantar-Zadeh
Journal:  Curr Heart Fail Rep       Date:  2017-10

5.  B-type natriuretic peptide is not a volume marker among patients on hemodialysis.

Authors:  Rajiv Agarwal
Journal:  Nephrol Dial Transplant       Date:  2013-03-22       Impact factor: 5.992

6.  Importance of the curve shape for interpretation of blood volume monitor changes during haemodiafiltration.

Authors:  Céline Dheu; Joelle Terzic; Soraya Menouer; Michel Fischbach
Journal:  Pediatr Nephrol       Date:  2009-03-07       Impact factor: 3.714

7.  Relative plasma volume monitoring during hemodialysis AIDS the assessment of dry weight.

Authors:  Arjun D Sinha; Robert P Light; Rajiv Agarwal
Journal:  Hypertension       Date:  2009-12-28       Impact factor: 10.190

8.  Greater fluid overload and lower interdialytic weight gain are independently associated with mortality in a large international hemodialysis population.

Authors:  Manfred Hecking; Ulrich Moissl; Bernd Genser; Hugh Rayner; Indranil Dasgupta; Stefano Stuard; Andrea Stopper; Charles Chazot; Franklin W Maddux; Bernard Canaud; Friedrich K Port; Carmine Zoccali; Peter Wabel
Journal:  Nephrol Dial Transplant       Date:  2018-10-01       Impact factor: 5.992

9.  All-cause mortality in relation to changes in relative blood volume during hemodialysis.

Authors:  Priscila Preciado; Hanjie Zhang; Stephan Thijssen; Jeroen P Kooman; Frank M van der Sande; Peter Kotanko
Journal:  Nephrol Dial Transplant       Date:  2019-08-01       Impact factor: 5.992

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.