Literature DB >> 8836217

Mechanical states encoded by stretch-sensitive neurons in feline joint capsule.

P S Khalsa1, A H Hoffman, P Grigg.   

Abstract

1. The sensitivity of group II joint afferents innervating cat knee joint capsule to in-plane stretch was studied in vitro. Single afferents were recorded from teased filaments of the posterior articular nerve. The capsule was stretched by applying forces through tabs along the edges of the capsule (3 tabs/edge) with the use of an apparatus that allowed for independent control of each load. The relationships between the neural responses of these afferents and the local continuum mechanical state of the joint capsule have been investigated. By appropriately loading the tissue margins, it was possible to establish states of uniaxial and biaxial tension, including shear. 2. Plane stress was calculated from the loads along the tissue margins. Stress at the location of the mechanoreceptor ending was estimated by interpolation. Strain was calculated from deformations of the capsule measured by tracking markers on its surface. Full characterization of tissue stress and strain made it possible to determine strain energy density and the magnitudes of other coordinate invariant mechanical quantities. 3. Individual afferents (n = 15) exhibited pronounced selectivity to the direction of applied stress and strain. There was no overall preferred orientation across neurons, and simple correlation of individual stress or strain components with the neuronal response revealed no consistent relationship between neuronal response and any single tensor component. However, linear multiple regression of the combined stress and strain components with the neuronal response revealed high correlation (mean R = 0.91), indicating that the measured mechanical states strongly determine the neuronal response. There was a much stronger relationship between neuronal response and stress variables than with strain variables. Simple correlation of the first invariant of the stress tensor with neuronal response had the highest mean correlation of the tensor quantities (R = 0.51). On average, strain energy density was only modestly correlated with the neural response (R = 0.28). 4. These findings indicate that capsule mechanoreceptors are encoding the local continuum mechanical state in the joint capsule. The neural response of these mechanoreceptors is more strongly correlated to local stress than to local strain.

Mesh:

Year:  1996        PMID: 8836217     DOI: 10.1152/jn.1996.76.1.175

Source DB:  PubMed          Journal:  J Neurophysiol        ISSN: 0022-3077            Impact factor:   2.714


  13 in total

1.  Development of an in vivo method to investigate biomechanical and neurophysiological properties of spine facet joint capsules.

Authors:  Ying Lu; Chaoyang Chen; Srinivasu Kallakuri; Ajit Patwardhan; John M Cavanaugh
Journal:  Eur Spine J       Date:  2005-02-03       Impact factor: 3.134

2.  Model-based ankle joint angle tracing by cuff electrode recordings of peroneal and tibial nerves.

Authors:  Chou-Ching K Lin; Ming-Shaung Ju; Hang-Shing Cheng
Journal:  Med Biol Eng Comput       Date:  2007-02-02       Impact factor: 2.602

3.  Comparison of human lumbar facet joint capsule strains during simulated high-velocity, low-amplitude spinal manipulation versus physiological motions.

Authors:  Allyson Ianuzzi; Partap S Khalsa
Journal:  Spine J       Date:  2005 May-Jun       Impact factor: 4.166

4.  Relationships between joint motion and facet joint capsule strain during cat and human lumbar spinal motions.

Authors:  Allyson Ianuzzi; Joel G Pickar; Partap S Khalsa
Journal:  J Manipulative Physiol Ther       Date:  2011-06-24       Impact factor: 1.437

5.  Collagen organization regulates stretch-initiated pain-related neuronal signals in vitro: Implications for structure-function relationships in innervated ligaments.

Authors:  Sijia Zhang; Sagar Singh; Beth A Winkelstein
Journal:  J Orthop Res       Date:  2017-08-11       Impact factor: 3.494

6.  Validating a population model of tactile mechanotransduction of slowly adapting type I afferents at levels of skin mechanics, single-unit response and psychophysics.

Authors:  Gregory J Gerling; Isabelle I Rivest; Daine R Lesniak; Jacob R Scanlon; Lingtian Wan
Journal:  IEEE Trans Haptics       Date:  2014 Apr-Jun       Impact factor: 2.487

7.  A continuum mechanical model of mechanoreceptive afferent responses to indented spatial patterns.

Authors:  Arun P Sripati; Sliman J Bensmaia; Kenneth O Johnson
Journal:  J Neurophysiol       Date:  2006-02-15       Impact factor: 2.714

8.  A nonlinear anisotropic inverse method for computational dissection of inhomogeneous planar tissues.

Authors:  Colleen M Witzenburg; Victor H Barocas
Journal:  Comput Methods Biomech Biomed Engin       Date:  2016-05-02       Impact factor: 1.763

9.  Evidence of gender-specific motor templates to resist valgus loading at the knee.

Authors:  Martha L Cammarata; Yasin Y Dhaher
Journal:  Muscle Nerve       Date:  2010-05       Impact factor: 3.217

10.  Tissue Strain Reorganizes Collagen With a Switchlike Response That Regulates Neuronal Extracellular Signal-Regulated Kinase Phosphorylation In Vitro: Implications for Ligamentous Injury and Mechanotransduction.

Authors:  Sijia Zhang; Xuan Cao; Alec M Stablow; Vivek B Shenoy; Beth A Winkelstein
Journal:  J Biomech Eng       Date:  2016-02       Impact factor: 2.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.