Literature DB >> 8835973

Spiral CT angiography of the thoracic aorta.

J W Chung1, J H Park, J G Im, M J Chung, M C Han, H Ahn.   

Abstract

Computed tomographic (CT) angiography is a new minimally invasive vascular imaging modality. FOr its clinical use to increase, the advantages and potential applications of this modality must be understood. The clinical applications of CT angiography in the thoracic aorta and its branches include evaluation of congenital aortic anomalies, aortic aneurysm, aortic dissection, Takayasu arteritis, penetrating aortic atherosclerotic ulcer, traumatic aortic injury, the postoperative aorta, arch vessels, and pulmonary sequestration. The advantages of CT angiography over conventional angiography are as follows: (a) high-quality, thin axial sections that demonstrate mural changes, extraluminal pathologic conditions, and spatial relationships with adjacent organs; (b) high contrast resolution and high sensitivity for detecting calcified lesions; (c) angiographic or three-dimensional display of vascular structures and adjacent organs in any projection with a single spiral acquisition; and (d) demonstration of extrinsic causes of vascular compromise. CT angiography has the potential to replace conventional catheter angiography in the diagnosis of many pathologic conditions of the thoracic aorta.

Entities:  

Mesh:

Year:  1996        PMID: 8835973     DOI: 10.1148/radiographics.16.4.8835973

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  4 in total

1.  A morphometric study on cadaveric aortic arch and its major branches in 25 korean adults : the perspective of endovascular surgery.

Authors:  Il-Young Shin; Yong-Gu Chung; Won-Han Shin; Soo-Bin Im; Sun-Chul Hwang; Bum-Tae Kim
Journal:  J Korean Neurosurg Soc       Date:  2008-08-30

2.  Radiological profile of anemia on unenhanced MDCT of the thorax.

Authors:  Ehab M Kamel; Elena Rizzo; Michel A Duchosal; Rafael Duran; Vasco Goncalves-Matoso; Pierre Schnyder; Salah D Qanadli
Journal:  Eur Radiol       Date:  2008-04-02       Impact factor: 5.315

3.  Stroke severity predicted by aortic atheroma detected by ultra-fast and cardiac-gated chest tomography.

Authors:  Marc A Lazzaro; Osama O Zaidat; Mohammad A Issa; Robert C Gilkeson; Jeffrey L Sunshine; Robert W Tarr; Shakir Husain; Jose I Suarez
Journal:  Front Neurol       Date:  2011-03-21       Impact factor: 4.003

4.  The ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography.

Authors:  Ying Liu; Jian Xu; Jian Li; Jing Ren; Hongtao Liu; Junqing Xu; Mengqi Wei; Yuewen Hao; Minwen Zheng
Journal:  J Cardiothorac Surg       Date:  2013-12-12       Impact factor: 1.637

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.