Literature DB >> 8835837

Analysis of pressurized resistance vessel diameter changes with a low cost digital image processing device.

J G Fischer1, H Mewes, H H Hopp, R Schubert.   

Abstract

A low cost digital image processing device (frame grabber) together with a program running under MS_WINDOWS for automatic on-line analysis of diameter changes of in vitro pressurized blood vessels with an inner diameter of 80-400 microns is presented. The frame grabber is designed to receive light microscopic images either from a video camera or from a VCR and to present the digitized image on the computer monitor. The special software allows to manipulate the image, e.g. filtering, calibrating, storing of vessel images, and detects the outer and inner border of the two vessel walls with a new, simple algorithm. The inner diameter and the vessel wall thickness are calculated and the diameter is presented in a diameter versus time diagram on the monitor screen. Further, these data are stored in an ASCII-file for later import into calculation and presentation programs like MS-EXCEL.

Mesh:

Year:  1996        PMID: 8835837     DOI: 10.1016/0169-2607(96)01726-9

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  7 in total

1.  Modulation of the myogenic response by neurogenic influences in rat small arteries.

Authors:  Stephanie Anschütz; Rudolf Schubert
Journal:  Br J Pharmacol       Date:  2005-09       Impact factor: 8.739

2.  Src tyrosine kinases contribute to serotonin-mediated contraction by regulating calcium-dependent pathways in rat skeletal muscle arteries.

Authors:  Olga Zavaritskaya; Lubomir T Lubomirov; Serdar Altay; Rudolf Schubert
Journal:  Pflugers Arch       Date:  2017-02-11       Impact factor: 3.657

3.  Dose-response relationship of locally applied nimodipine in an ex vivo model of cerebral vasospasm.

Authors:  Fatih Seker; Jürgen Hesser; Eva Neumaier-Probst; Christoph Groden; Marc A Brockmann; Rudolf Schubert; Carolin Brockmann
Journal:  Neuroradiology       Date:  2012-08-05       Impact factor: 2.804

4.  Fast retinal vessel detection and measurement using wavelets and edge location refinement.

Authors:  Peter Bankhead; C Norman Scholfield; J Graham McGeown; Tim M Curtis
Journal:  PLoS One       Date:  2012-03-12       Impact factor: 3.240

5.  VasoTracker, a Low-Cost and Open Source Pressure Myograph System for Vascular Physiology.

Authors:  Penelope F Lawton; Matthew D Lee; Christopher D Saunter; John M Girkin; John G McCarron; Calum Wilson
Journal:  Front Physiol       Date:  2019-02-21       Impact factor: 4.566

6.  The Functional Availability of Arterial Kv7 Channels Is Suppressed Considerably by Large-Conductance Calcium-Activated Potassium Channels in 2- to 3-Month Old but Not in 10- to 15-Day Old Rats.

Authors:  Dongyu Ma; Dina Gaynullina; Nadine Schmidt; Mitko Mladenov; Rudolf Schubert
Journal:  Front Physiol       Date:  2020-12-15       Impact factor: 4.566

7.  Vasodilation of rat skeletal muscle arteries by the novel BK channel opener GoSlo is mediated by the simultaneous activation of BK and Kv 7 channels.

Authors:  Olga Zavaritskaya; Srikanth Dudem; Dongyu Ma; Kaneez E Rabab; Sarah Albrecht; Dmitry Tsvetkov; Mario Kassmann; Keith Thornbury; Mitko Mladenov; Claire Kammermeier; Gerard Sergeant; Nicholas Mullins; Ornella Wouappi; Hannah Wurm; Aimo Kannt; Maik Gollasch; Mark A Hollywood; Rudolf Schubert
Journal:  Br J Pharmacol       Date:  2020-01-26       Impact factor: 8.739

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.