Literature DB >> 8833648

Performance of immunoassays for ca 19-9, ca 15-3 and ca 125 tumour markers evaluated from an international quality assessment survey.

A Pilo1, G C Zucchelli, R Cohen, M R Chiesa, C A Bizollon.   

Abstract

Data collected in the 1993 and 1994 cycles of an international External Quality Assessment (EQA) programme were cumulatively analysed to evaluate the analytical performance of the methods currently in use for routine assay of mucinous tumour markers CA 19-9, CA 15-3 and CA 125. On average the between-laboratory variability was 14.7 and 15.8 CV% for CA 15-3 and CA 125 respectively. For CA 19-9, a markedly worse between-laboratory variability (on average 27.2 CV%) was found; the agreement of CA 19-9 results worsened in the last few years when new isotopic techniques became available. The variability component attributable to systematic differences between methods/kits was relatively small for CA 15-3 and CA 125 (17% and 21% of the total variability), while it was markedly larger for CA 19-9 (45% of the total variability). The precision of the methods/kits most often used in the survey ranged from 9.6 to 13.9 CV% for CA 125 and from 10.8 to 14.1 CV% for CA 15-3. For these two tumour markers the precision of the traditional IRMAs does not appear to be different from that of the new fully automated non-isotopic techniques. The precision of CA 19-9 methods was on average worse from (11.9 to 19.2 CV%), even though the precision of the two automated systems was better than that of IRMAs. In conclusion, the results of this study indicate that the between-laboratory agreement for CA 15-3 and CA 125 assays appears satisfactory while the CA 19-9 assay shows larger differences between methods and is affected by poorer precision of kits.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8833648     DOI: 10.1515/cclm.1996.34.2.145

Source DB:  PubMed          Journal:  Eur J Clin Chem Clin Biochem        ISSN: 0939-4974


  2 in total

1.  Glycan motif profiling reveals plasma sialyl-lewis x elevations in pancreatic cancers that are negative for sialyl-lewis A.

Authors:  Huiyuan Tang; Sudhir Singh; Katie Partyka; Doron Kletter; Peter Hsueh; Jessica Yadav; Elliot Ensink; Marshall Bern; Galen Hostetter; Douglas Hartman; Ying Huang; Randall E Brand; Brian B Haab
Journal:  Mol Cell Proteomics       Date:  2015-03-02       Impact factor: 5.911

2.  Evaluation of a CLEIA automated assay system for the detection of a panel of tumor markers.

Authors:  Renato Falzarano; Valentina Viggiani; Simona Michienzi; Flavia Longo; Silvestra Tudini; Luigi Frati; Emanuela Anastasi
Journal:  Tumour Biol       Date:  2013-06-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.