Literature DB >> 8825383

The noninvasive measurement of absolute cerebral deoxyhemoglobin concentration and mean optical path length in the neonatal brain by second derivative near infrared spectroscopy.

C E Cooper1, C E Elwell, J H Meek, S J Matcher, J S Wyatt, M Cope, D T Delpy.   

Abstract

We have used second differential near infrared spectroscopy of water to determine the mean optical path length of the neonatal brain. By obtaining the ratio of the second differential features of deoxyhemoglobin to those of water, the absolute cerebral concentration of deoxyhemoglobin can be monitored continuously and noninvasively. Nineteen neonates were studied; the gestational age at birth varied from 23 to 38 wk, and the postconceptual age, when the spectra were recorded, ranged from 35 to 48 wk. The calculated mean deoxyhemoglobin concentration was 14.6 +/- 4.0 microM; the differential path length factor (mean optical path length/optode separation) calculated from the water peak at 730 nm was 4.66 +/- 1.01, and that calculated at the 830-nm peak was 3.91 +/- 0.75. These values are consistent with path length measurements using laser time-of-flight spectroscopy on postmortem neonates and phase-resolved spectroscopy on live neonates. Induced arterial oxygen saturation decreases from 98 to 93% showed no significant change in the mean optical path length, despite significant cerebral desaturation. Changes in the deoxyhemoglobin concentration after this procedure were identical, whether measured by second differential analysis at 760 nm or by multilinear regression over the wavelength range 740-900 nm. When combined with existing methods of measuring total cerebral hemoglobin concentration, second differential near infrared spectroscopy can be used to derive the mean cerebral oxygen saturation. A preliminary experiment outlined the feasibility of this approach and yielded a saturation value of 63%, consistent with near infrared sampling of a predominantly venous pool in the brain.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8825383     DOI: 10.1203/00006450-199601000-00005

Source DB:  PubMed          Journal:  Pediatr Res        ISSN: 0031-3998            Impact factor:   3.756


  22 in total

1.  Abnormal cerebral haemodynamics in perinatally asphyxiated neonates related to outcome.

Authors:  J H Meek; C E Elwell; D C McCormick; A D Edwards; J P Townsend; A L Stewart; J S Wyatt
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-09       Impact factor: 5.747

Review 2.  Haemoglobin oxygen saturation as a biomarker: the problem and a solution.

Authors:  David A Boas; Maria Angela Franceschini
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2011-11-28       Impact factor: 4.226

3.  Noninvasive monitoring of cerebral oxygenation in traumatic brain injury: a mix of doubts and hope.

Authors:  Andrew I R Maas; Giuseppe Citerio
Journal:  Intensive Care Med       Date:  2010-05-26       Impact factor: 17.440

4.  Application of spectral derivative data in visible and near-infrared spectroscopy.

Authors:  Hamid Dehghani; Frederic Leblond; Brian W Pogue; Fabien Chauchard
Journal:  Phys Med Biol       Date:  2010-05-26       Impact factor: 3.609

5.  Algorithm for mapping cutaneous tissue oxygen concentration using hyperspectral imaging.

Authors:  Sorin Miclos; Sorin Viorel Parasca; Mihaela Antonina Calin; Dan Savastru; Dragos Manea
Journal:  Biomed Opt Express       Date:  2015-08-18       Impact factor: 3.732

6.  Wavelet analysis used for spectral background removal in the determination of glucose from near-infrared single-beam spectra.

Authors:  Boyong Wan; Gary W Small
Journal:  Anal Chim Acta       Date:  2010-09-22       Impact factor: 6.558

7.  [Bilateral nasal remission spectroscopy allows the side separated continuous measurement of changes in swelling of the nasal mucosa].

Authors:  E G Wüstenberg; U Hampel; E Schleicher; K-B Hüttenbrink; T Zahnert
Journal:  HNO       Date:  2007-04       Impact factor: 1.284

Review 8.  Numerical modelling and image reconstruction in diffuse optical tomography.

Authors:  Hamid Dehghani; Subhadra Srinivasan; Brian W Pogue; Adam Gibson
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2009-08-13       Impact factor: 4.226

9.  The relationship of oxygen delivery to absolute haemoglobin oxygenation and mitochondrial cytochrome oxidase redox state in the adult brain: a near-infrared spectroscopy study.

Authors:  C E Cooper; D T Delpy; E M Nemoto
Journal:  Biochem J       Date:  1998-06-15       Impact factor: 3.857

10.  Tissue hemoglobin index: a non-invasive optical measure of total tissue hemoglobin.

Authors:  Dean Myers; Michelle McGraw; Mark George; Kristine Mulier; Greg Beilman
Journal:  Crit Care       Date:  2009-11-30       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.