Literature DB >> 8823671

Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation.

M B Silver-Thorn1, D S Childress.   

Abstract

A finite element (FE) model of the below-knee residual limb and prosthetic socket was created to investigate the effects of parameter variations on the interface stress distribution during static stance. This model was based upon geometric approximations of anthropometric residual limb geometry. The model was not specific to an individual with amputation, but could be scaled to approximate the limb of a particular subject. Parametric analyses were conducted to investigate the effects of prosthetic socket design and residual limb geometry on the residual limb/prosthetic socket interface stresses. Behavioral trends were illustrated via sensitivity analysis. The results of the parametric analyses indicate that the residual limb/prosthetic socket interface stresses are affected by variations in both prosthetic design and residual limb geometry. Specifically, the analyses indicate: 1) the residual limb/prosthetic liner interface pressures are relatively insensitive to the socket stiffness; 2) the stiffness of the prosthetic liner influences the interface stress distribution for both the unrectified and patellar-tendon-bearing (PTB) rectified models-the external load state appears to influence the interface pressure distribution, while the prosthetic socket rectification appears to influence the interface shear stress distribution; 3) the interface pressures are very sensitive to the prosthetic rectification; 4) the shape and relative bulk of soft tissue may significantly influence the interface pressure distribution; 5) the interface pressure distribution is also influenced by the residual limb length; and 6) the stiffness/compliance of the residual limb soft tissues may significantly alter the interface pressure distribution.

Entities:  

Mesh:

Year:  1996        PMID: 8823671

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  3 in total

Review 1.  How a diverse research ecosystem has generated new rehabilitation technologies: Review of NIDILRR's Rehabilitation Engineering Research Centers.

Authors:  David J Reinkensmeyer; Sarah Blackstone; Cathy Bodine; John Brabyn; David Brienza; Kevin Caves; Frank DeRuyter; Edmund Durfee; Stefania Fatone; Geoff Fernie; Steven Gard; Patricia Karg; Todd A Kuiken; Gerald F Harris; Mike Jones; Yue Li; Jordana Maisel; Michael McCue; Michelle A Meade; Helena Mitchell; Tracy L Mitzner; James L Patton; Philip S Requejo; James H Rimmer; Wendy A Rogers; W Zev Rymer; Jon A Sanford; Lawrence Schneider; Levin Sliker; Stephen Sprigle; Aaron Steinfeld; Edward Steinfeld; Gregg Vanderheiden; Carolee Winstein; Li-Qun Zhang; Thomas Corfman
Journal:  J Neuroeng Rehabil       Date:  2017-11-06       Impact factor: 4.262

2.  Clinical implication of interface pressure for a new prosthetic suspension system.

Authors:  Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Nasrul Anuar Abd Razak
Journal:  Biomed Eng Online       Date:  2014-06-30       Impact factor: 2.819

3.  Analysis of Pressure Distribution in Transfemoral Prosthetic Socket for Prefabrication Evaluation via the Finite Element Method.

Authors:  Mohd Syahmi Jamaludin; Akihiko Hanafusa; Yamamoto Shinichirou; Yukio Agarie; Hiroshi Otsuka; Kengo Ohnishi
Journal:  Bioengineering (Basel)       Date:  2019-10-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.