Literature DB >> 8821898

Changes in left ventricular volume and systolic function before and after the closure of ductus arteriosus in full-term infants.

Y Takahashi1, K Harada, A Ishida, M Tamura, T Tanaka, G Takada.   

Abstract

Using echocardiographic techniques, the change in left ventricular (LV) volume and its effect on systolic function were studied before and after the closure of ductus arteriosus in 18 full-term infants. Examinations were performed twice in each infant, within 6 h after birth and on day 5, and the patency of the ductus with left-to-right shunt was confirmed at the first examination by Doppler echocardiography. A biplane Simpson's rule method was used for volume measurements. The LV end-diastolic volume, stroke volume, and cardiac output were more than 1.3-fold before the ductal closure, and the ejection fraction showed the similar change. However, the mean normalized systolic ejection rate, an index of contractility, and heart rate showed no significant difference. The Frank-Starling curve was obtained from the relationship between the LV end-diastolic and stroke volumes, and the LV performance was operated at a higher level on that curve when the ductus was open. Our data indicated that LV cardiac output was significantly higher during the patency of the ductus arteriosus and that this high cardiac performance might depend more on the Frank-Starling response to the volume load through the ductus arteriosus than on the increase of LV contractility and heart rate.

Entities:  

Mesh:

Year:  1996        PMID: 8821898     DOI: 10.1016/0378-3782(95)01695-3

Source DB:  PubMed          Journal:  Early Hum Dev        ISSN: 0378-3782            Impact factor:   2.079


  8 in total

1.  Transient dynamic subaortic stenosis in premature neonates after patent ductus arteriosus ligation.

Authors:  Madhavi Sangem; Mubadda A Salim; Jon C Love; A Okogbule-Wonodi; Marcelo G Cardarelli
Journal:  Pediatr Cardiol       Date:  2007-11-13       Impact factor: 1.655

2.  Catecholamine-resistant hypotension and myocardial performance following patent ductus arteriosus ligation.

Authors:  S Noori; P McNamara; A Jain; P M Lavoie; A Wickremasinghe; T A Merritt; T Solomon; K Sekar; J T Attridge; J R Swanson; M Gillam-Krakauer; J Reese; B B Poindexter; M Brook; R J Auchus; R I Clyman
Journal:  J Perinatol       Date:  2014-08-14       Impact factor: 2.521

3.  Steel reinforced composite silicone membranes and its integration to microfluidic oxygenators for high performance gas exchange.

Authors:  Harpreet Matharoo; Mohammadhossein Dabaghi; Niels Rochow; Gerhard Fusch; Neda Saraei; Mohammed Tauhiduzzaman; Stephen Veldhuis; John Brash; Christoph Fusch; P Ravi Selvaganapathy
Journal:  Biomicrofluidics       Date:  2018-01-11       Impact factor: 2.800

4.  Myocardial contractility in premature neonates with and without patent ductus arteriosus.

Authors:  A J Barlow; C Ward; S A Webber; B G Sinclair; J E Potts; G G S Sandor
Journal:  Pediatr Cardiol       Date:  2003-12-04       Impact factor: 1.655

5.  Echocardiographic evaluation of myocardial changes observed after closure of patent ductus arteriosus in dogs.

Authors:  L Hamabe; S Kim; R Yoshiyuki; T Fukayama; T M Nakata; R Fukushima; R Tanaka
Journal:  J Vet Intern Med       Date:  2015-01-16       Impact factor: 3.333

6.  Evaluation of left ventricular dimension and systolic function by standard transthoracic echocardiography before and 24-hours after percutaneous closure of patent ductus arteriosus in 120 dogs.

Authors:  Diego Piantedosi; Alfonso Piscitelli; Angela De Rosa; Blanca Serrano Lopez; Marta Claretti; Elisabetta Boz; Laura Mazzoni; Iolanda Navalon Calvo; Paolo Ciaramella; Claudio Bussadori
Journal:  PLoS One       Date:  2019-10-09       Impact factor: 3.240

7.  Transient left ventricular systolic dysfunction following surgical closure of large patent ductus arteriosus among children and adolescents operated at the cardiac centre, Ethiopia.

Authors:  Birkneh Tilahun; Endale Tefera
Journal:  J Cardiothorac Surg       Date:  2013-05-31       Impact factor: 1.637

8.  Long-term outcome in dogs with patent ductus arteriosus: 520 cases (1994-2009).

Authors:  A B Saunders; S G Gordon; M M Boggess; M W Miller
Journal:  J Vet Intern Med       Date:  2013-12-26       Impact factor: 3.333

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.