Analysis of strain at selected bone sites of a cantilevered implant-supported prosthesis.

E A Tashkandi1, B R Lang, M J Edge.   

Abstract

Cantilever length of the superstructure of an implant-supported prosthesis can be affected by the location, number, and dimensions of the implants, arch form, opposing dentition, and functionally generated forces. In this study, the effects of cantilever length on load distribution to implants was analyzed. A fresh bovine rib was used to create a clinical simulation in which three implants were used to support an implant prosthesis. The implants were connected by means of a cantilevered superstructure. Six linear strain gauges were placed in strategic locations where it has been reported that stress is concentrated. The model was loaded with an Instron machine and the load was applied at 0, 5, 10, 15, 20 and 25 mm along the cantilever length. Each loading test was repeated five times, and loads of 10 and 20 pounds were applied. Dynamic registration of the strain was recorded at each gauge. Significant differences in the magnitude of strain between the six strain gauge locations were recorded with the 10 and 20 lb loads and at all cantilevered lengths. The results revealed that the greatest maximum strain occurred at the strain gauge positioned on cortical bone over the apex of the most distal implant under both loading conditions.

Entities:  

Mesh:

Year:  1996        PMID: 8820807     DOI: 10.1016/s0022-3913(96)90300-5

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Determination of strain around distal implants as abutments for partial and fixed implant-supported prostheses with posterior cantilever.

Authors:  Roodabeh Koodaryan; Neda Yasamineh; Ali Hafezeqoran; Sheida Monem Moharrer; Seyed Gholamreza Noorazar
Journal:  J Adv Pharm Technol Res       Date:  2022-04-07

2.  Split-Framework in Mandibular Implant-Supported Prosthesis.

Authors:  Danny Omar Mendoza Marin; Kássia de Carvalho Dias; André Gustavo Paleari; Ana Carolina Pero; João Neudenir Arioli Filho; Marco Antonio Compagnoni
Journal:  Case Rep Dent       Date:  2015-12-03

3.  Influence of Framework Material and Posterior Implant Angulation in Full-Arch All-on-4 Implant-Supported Prosthesis Stress Concentration.

Authors:  João Paulo Mendes Tribst; Dayana Campanelli de Morais; Jefferson David Melo de Matos; Guilherme da Rocha Scalzer Lopes; Amanda Maria de Oliveira Dal Piva; Alexandre Luiz Souto Borges; Marco Antonio Bottino; Antonio Lanzotti; Massimo Martorelli; Pietro Ausiello
Journal:  Dent J (Basel)       Date:  2022-01-14

4.  Effect of joining the sectioned implant-supported prosthesis on the peri-implant strain generated in simulated mandibular model.

Authors:  Ipsha Singh; K Chandrasekharan Nair; Jayakar Shetty
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.