Literature DB >> 8818901

Dot-immunogold filtration assay as a screening test for syphilis.

Q Huang1, X Lan, T Tong, X Wu, M Chen, X Feng, R Liu, Y Tang, Z Zhu.   

Abstract

A dot-immunogold filtration assay (DIGFA) for the rapid detection of reaginic antibody in the serum of syphilitic patients was developed. The assay was simple, rapid, and reproducible. The test completion time was 2 min, and the assay required no equipment. The positive dot was very obvious, and the results could easily be determined with the naked eye. A total of 350 serum samples were examined by DIGFA, the rapid plasma reagin test, and the fluorescent treponemal antibody-absorption test. The levels of agreement between DIGFA and the rapid reagin test and between DIGFA and the fluorescent treponemal antibody-absorption test were 100 and 98%, respectively. The results of clinical application indicated that DIGFA could be used as a routine screening test for syphilis.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8818901      PMCID: PMC229173          DOI: 10.1128/jcm.34.8.2011-2013.1996

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  3 in total

1.  Labelling of colloidal gold with protein A. A quantitative study.

Authors:  M Horisberger; M F Clerc
Journal:  Histochemistry       Date:  1985

2.  Comparison of a hemagglutination treponemal test for syphilis (HATTS) with other serologic methods for the diagnosis of syphilis.

Authors:  B B Wentworth; M A Thompson; C R Peter; R E Bawdon; D L Wilson
Journal:  Sex Transm Dis       Date:  1978 Jul-Sep       Impact factor: 2.830

3.  Evaluation of the qualitative and automated quantitative microhemagglutination assay for antibodies to Treponema pallidum.

Authors:  E M Coffey; L L Bradford; L S Naritomi; R M Wood
Journal:  Appl Microbiol       Date:  1972-07
  3 in total
  3 in total

1.  Serum anticardiolipin antibodies in patients with neuromyelitis optica spectrum disorder.

Authors:  Youming long; Yihua He; Yangbo Zheng; Mengyu Chen; Bin Zhang; Cong Gao
Journal:  J Neurol       Date:  2013-12       Impact factor: 4.849

2.  Evaluation of Dot Immunogold Filtration Assay (DIGFA) By Recombinant Protein EPC1 for Anti- Echinococcus granulosus IgG Antibody.

Authors:  Somayeh Kordafshari; Seyed Hossein Hosseini; Fatemeh Jalousian; Masoumeh Rajabibazl; Malcolm Jones; Fazeleh Etebar
Journal:  Iran J Parasitol       Date:  2015 Jan-Mar       Impact factor: 1.012

3.  Are Treponema pallidum specific rapid and point-of-care tests for syphilis accurate enough for screening in resource limited settings? Evidence from a meta-analysis.

Authors:  Yalda Jafari; Rosanna W Peeling; Sushmita Shivkumar; Christiane Claessens; Lawrence Joseph; Nitika Pant Pai
Journal:  PLoS One       Date:  2013-02-26       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.