Literature DB >> 8818308

Theoretical relationship of lung deposition to the fine particle fraction of inhalation aerosols.

A J Hickey1, T B Martonen, Y Yang.   

Abstract

Pharmaceutical inhalation aerosols intended to deliver drugs to the lungs may be sampled by inertial devices, that divide particle distributions into pre-calibrated diameters. A characteristic particle diameter (D50) is prescribed, below which the aerosol mass is designated the 'respirable fraction'. The following studies compare designated respirable fractions with predicted lower lung deposition. Designated respirable fractions (% of particulate matter < 6.4 microns or alternatively < 9.8 microns) of 30, 40 and 50% were selected to represent typical inhalation aerosols. The compendial inertial samplers used to aerodynamically characterize the particle size of pharmaceutical aerosols operate at approximately 30 or 60 l/min. These values were selected as the volumetric flow rates (Qv) for a mathematical model of lung deposition. The model was employed to predict the lung deposition of particle size distributions giving rise to each designated respirable fraction. Nominal tidal volumes (Tv) of 500 and 1622 ml were adopted at appropriate breathing frequencies to accommodate the designated Qv. Predicted lung depositions (+/- range due to particle size) of 1.4 +/- 0.6%, at a respirable fraction of 30% (Qv = 60 l/min, Tv = 500 ml, D50 = 9.8 microns), and 20.9 +/- 3.6%, at a respirable fraction of 50% (Qv = 30 l/min., Tv = 1622 ml, D50 = 6.4 microns) illustrate the range of results obtained. Under well defined conditions there appeared to be a qualitative correlation between respirable fraction and predicted lower lung deposition. However, this was influenced by the aerosol particle size distribution and breathing parameters.

Mesh:

Substances:

Year:  1996        PMID: 8818308     DOI: 10.1016/0031-6865(96)00014-3

Source DB:  PubMed          Journal:  Pharm Acta Helv        ISSN: 0031-6865


  6 in total

1.  Micronization of a soft material: air-jet and micro-ball milling.

Authors:  Imran Y Saleem; Hugh D C Smyth
Journal:  AAPS PharmSciTech       Date:  2010-11-24       Impact factor: 3.246

2.  Estimating the number of droplets and drug particles emitted from MDIs.

Authors:  Stephen W Stein
Journal:  AAPS PharmSciTech       Date:  2008-01-17       Impact factor: 3.246

Review 3.  Mechanisms of pharmaceutical aerosol deposition in the respiratory tract.

Authors:  Yung Sung Cheng
Journal:  AAPS PharmSciTech       Date:  2014-02-22       Impact factor: 3.246

Review 4.  Process optimization and particle engineering of micronized drug powders via milling.

Authors:  A Brunaugh; H D C Smyth
Journal:  Drug Deliv Transl Res       Date:  2018-12       Impact factor: 4.617

5.  Formulation and characterization of lipid-coated tobramycin particles for dry powder inhalation.

Authors:  Gabrielle Pilcer; Thami Sebti; Karim Amighi
Journal:  Pharm Res       Date:  2006-05-02       Impact factor: 4.200

6.  Metal rich particulate matter impairs acetylcholine-mediated vasorelaxation of microvessels in mice.

Authors:  Azita K Cuevas; Jingping Niu; Mianhua Zhong; Eric N Liberda; Andrew Ghio; Qingshan Qu; Lung Chi Chen
Journal:  Part Fibre Toxicol       Date:  2015-06-04       Impact factor: 9.400

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.