AIMS: Anatomical and electrogram-guided techniques have been used separately for slow pathway ablation in atrioventricular nodal reentrant tachycardia. The aims of the present study were to analyse electrogram characteristics of target sites and biophysical parameters using a combined anatomical and electrogram-guided technique for temperature-controlled radiofrequency catheter ablation of the slow pathway. METHODS AND
RESULTS: Using a temperature-controlled (pre-selected 60 degrees C) catheter system, 53 patients with atrioventricular nodal reentrant tachycardia underwent slow pathway radiofrequency ablation. Mapping was started posteroseptally near the coronary sinus ostium and continued towards the midseptal area if needed. The longest and latest atrial electrograms with an atrioventricular ratio of < or = 0.5 were targeted. After a median of two pulses (mean 2.36 +/- 1.33), atrioventricular nodal reentrant tachycardia was rendered non-inducible in all patients without complications. Successful sites had longer atrial electrograms (78.8 +/- 9.8 vs 67.6 +/- 13.3 ms, P < 0.003) and larger ventricular electrogram amplitudes (92.4 +/- 51.2 vs 63.1 +/- 28.8 mV, P < 0.05) than the failed sites, but had a similar atrioventricular ratio, P-A interval and atrial electrogram amplitude. Overall, an atrial electrogram duration of > or = 70 ms was associated with effective radiofrequency delivery, with 86% sensitivity and 62% specificity. The achieved temperature maximum was 62.3 +/- 9.8 degrees C at successful and 58.8 +/- 9.0 degrees C at unsuccessful sites (ns). There was no significant difference between successful and unsuccessful applications with respect to power output, impedance and total delivery energy. During a pre-discharge study, three patients with inducible atrioventricular nodal reentrant tachycardia underwent a repeat ablation. During 12.3 +/- 2.5 (6-15) months of follow-up, three others had a clinical recurrence of atrioventricular nodal reentrant tachycardia.
CONCLUSIONS: The combined approach for slow pathway ablation is highly effective, requiring a low number of radiofrequency pulses. Long atrial activation time seems to be the most powerful predictor of success. Similar catheter tip temperature levels during successful and unsuccessful radiofrequency applications indicate that suboptimal selection of target sites rather than ineffective heating due to poor catheter tissue coupling is responsible for unsuccessful energy delivery.

Entities:  

Mesh:

Year:  1996        PMID: 8809528     DOI: 10.1093/oxfordjournals.eurheartj.a015006

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  4 in total

1.  Role of isoproterenol in predicting the success of catheter ablation in patients with reproducibly inducible atrioventricular nodal reentrant tachycardia.

Authors:  Alireza Heydari; Mohammad Tayyebi; Rahmatolah Damanpak Jami; Asgar Amiri
Journal:  Tex Heart Inst J       Date:  2014-06-01

2.  Electrophysiologic characteristics of different ectopic rhythms during slow pathway ablation in patients with atrioventricular nodal reentrant tachycardia.

Authors:  M H Hsieh; S A Chen; C T Tai; C E Chiang; M S Chang
Journal:  J Interv Card Electrophysiol       Date:  1998-06       Impact factor: 1.900

3.  An integrative approach to slow pathway modulation in AVNRT using a novel ultra high-density electroanatomical mapping system.

Authors:  Sebastian Hilbert; Jedrzej Kosiuk; Silke John; Gerhard Hindricks; Andreas Bollmann
Journal:  Clin Res Cardiol       Date:  2015-03-31       Impact factor: 5.460

4.  Outcome of slow pathway modulation for atrioventricular nodal reentrant tachycardia with 50 versus 30 watts-more power, more effect?

Authors:  Dirk G Dechering; Ruben Schleberger; Eva Greiser; Jannis Dickow; Julia Koebe; Gerrit Frommeyer; Stephan Willems; Lars Eckardt; Boris A Hoffmann; Kristina Wasmer
Journal:  J Interv Card Electrophysiol       Date:  2018-03-19       Impact factor: 1.900