Literature DB >> 8809253

In vitro changes in clips and bars used to retain implant overdentures.

J N Walton1, N D Ruse.   

Abstract

Although implant-retained overdentures are a less expensive alternative to fixed implant-supported prostheses in certain situations, problems with retentive clips fracturing and needing frequent replacement have been reported. This study compared baseline and posttest retention of metal and plastic clip-retained overdenture analogs and monitored surface changes in bars and clips throughout the testing process. A laboratory model was made with two implant analogs processed into an acrylic resin platform to which three bars were fitted. Two overdenture analogs were made and retained on the model with metal or plastic clips. Each bar-clip assembly was subjected to 5500 insertion and removal cycles to simulate 3 years of in vivo insertion and removal. Although the differences in retention between metal and plastic clips and between clips before and after testing were statistically significant, it is questionable whether they are clinically significant. Neither clip fracture nor loss occurred during this study, which suggests that it may be functional or parafunctional loading and not repeated insertion and removal of an implant overdenture that may cause the stated problems.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8809253     DOI: 10.1016/s0022-3913(05)80349-x

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  5 in total

1.  An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures.

Authors:  Abdalbseet A Fatalla; Ke Song; Tianfeng Du; Yingguang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2012-01-27

2.  New mini dental implant attachments versus O-ring attachment after cyclic aging: Analysis of retention strength and gap space.

Authors:  Abdalbseet A Fatalla; Ke Song; Ying-Guang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-06-06

3.  Comparative Evaluation of Retentive Properties of Two Compatible Ball Attachments in Mandibular Implant-Retained Overdentures: An In Vitro Study.

Authors:  Maryam Memarian; Simindokht Zarrati; Sedigheh Karimi; Mehran Bahrami
Journal:  J Dent (Tehran)       Date:  2018-03

4.  Comparison of changes in retentive force of three stud attachments for implant overdentures.

Authors:  Su-Min Kim; Jae-Won Choi; Young-Chan Jeon; Chang-Mo Jeong; Mi-Jung Yun; So-Hyoun Lee; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

5.  Effect of bar cross-section and female housing material on retention of mandibular implant bar overdentures: A comparative in vitro study.

Authors:  Elsayed A Abdel-Khalek; Abdullah M Ibrahim
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.