PURPOSE: The single major disadvantage of carotid endarterectomy (CEA) patch reconstruction with greater saphenous vein (GSV) is central patch rupture, which has a reported incidence of 0.5% to 4%. This is a prospective evaluation of the selective use of GSV for a CEA patch based on previously established vein diameter criteria.
METHODS: Between 1988 and mid-1995, 534 of 671 CEAs (80%) were reconstructed with GSVs that had a distended diameter > or = 3.5 mm. Thigh veins were used in all 252 women who underwent CEA. Of the 282 men who underwent CEA, 265 GSVs (94%) were harvested from below the knee and 17 from the thigh. During this period four thigh and 13 below-knee veins (3.2%) were rejected because the diameter was < 3.5 mm, and a synthetic patch was used instead. In 408 of the CEAs with GSV (76%) the vein rupture pressures and diameters were measured, the CEA geometry was measured, and the predicted CEA vein patch rupture pressures were calculated.
RESULTS: No GSV patches ruptured in this series. This compares favorably with three patch ruptures in 239 previous CEAs when no vein diameter criteria was used (p = 0.03). This also compares favorably with a multicenter series of 13 GSV patch ruptures (0.73%) in 1773 CEAs (p = 0.03) and with a single-center series of eight ruptures (0.47%) in 1699 CEAs (p = 0.05). GSV diameters were 4.9 +/- 0.9 mm (mean +/- 1 SD); vein rupture pressures, 3.9 +/- 1.5 atmospheres; carotid bulb major axis diameters, 12.5 +/- 1.6 mm; carotid bulb maximum diameters of curvature, 14.2 +/- 2.2 mm; and CEA patch rupture pressures, 1.3 +/- 0.6 atmospheres (range, 280 mm Hg to 4 atmospheres). CEA vein patch rupture pressure correlates positively with vein diameter (p < 0.001, slope), but there is wide variability (correlation coefficient = 0.39). The 14 CEAs (3.4%) with predicted rupture pressures < 400 mm Hg were performed with veins 3.5 to 5.5 mm in diameter (mean, 4.2 mm), and all had carotid bulb major axis diameters > 12 mm (mean, 15.3 mm). Eight of these CEAs were reconstructed with thigh veins.
CONCLUSIONS: Use of GSVs with a distended diameter > or = 3.5 mm for CEA patch reconstruction significantly reduces the probability of central patch rupture; however, a few CEAs reconstructed with veins > 3.5 mm in diameter and large carotid bulbs have predicted patch rupture pressures < 400 mm Hg. Because at times some veins will have rupture pressures lower than desirable, CEA reconstruction should be tailored to keep the carotid bulb major axis diameter < 13 mm.

Entities:  

Mesh:

Year:  1996        PMID: 8808956     DOI: 10.1016/s0741-5214(96)70190-8

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  8 in total

Review 1.  Current usage and future directions for the bovine pericardial patch.

Authors:  Xin Li; Yuanyuan Guo; Kenneth R Ziegler; Lynn S Model; Sammy D D Eghbalieh; Robert A Brenes; Susun T Kim; Chang Shu; Alan Dardik
Journal:  Ann Vasc Surg       Date:  2011-01-28       Impact factor: 1.466

Review 2.  Patches for carotid artery endarterectomy: current materials and prospects.

Authors:  Akihito Muto; Toshiya Nishibe; Herbert Dardik; Alan Dardik
Journal:  J Vasc Surg       Date:  2009-07       Impact factor: 4.268

3.  Outcomes of Carotid Endarterectomy with Primary Closure.

Authors:  Ivy Cheng; Krishna S Vyas; Santhosh Velaga; Daniel L Davenport; Sibu P Saha
Journal:  Int J Angiol       Date:  2017-03-14

4.  Carotid Endarterectomy.

Authors:  Takayuki Hara; Yurie Rai
Journal:  Adv Tech Stand Neurosurg       Date:  2022

5.  Selective Patch Angioplasty and Intraoperative Shunting in Carotid Endarterectomy: A Single-Center Review of 141 Procedures.

Authors:  Rahul Kapoor; Alexander I Evins; Joshua Marcus; Luigi Rigante; Mayumi Kubota; Philip E Stieg
Journal:  Cureus       Date:  2015-10-28

6.  Vein Patch Closure Using Below the Knee Greater Saphenous Vein for Femoral Endarterectomy Procedures is Not Always a Safe Choice.

Authors:  M Berner; Th Lattmann; Ph Stalder; P Wigger
Journal:  EJVES Short Rep       Date:  2017-11-07

7.  Biomechanical Aspects of Closing Approaches in Postcarotid Endarterectomy.

Authors:  Idit Avrahami; Dafna Raz; Oranit Bash
Journal:  Comput Math Methods Med       Date:  2018-10-28       Impact factor: 2.238

8.  Experimental comparative assay of tensile resistance of greater saphenous vein from ankle and groin.

Authors:  Carlos Eduardo Del Valle; Marcio Miyamotto; Jorge Rufino Ribas Timi
Journal:  J Vasc Bras       Date:  2021-06-25
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.