Literature DB >> 8805887

Central venous catheters revisited--infection rates and an assessment of the new Fibrin Analysing System brush.

P V van Heerden1, S A Webb, S Fong, C L Golledge, B L Roberts, W R Thompson.   

Abstract

Sixty-one consecutive patients in the Intensive Care Unit requiring central venous lines (CVC) for five or more days were randomized to receive either a standard triple lumen CVC (STD/CVC) or a silver sulphadiazine and chlorhexidine impregnated CVC (SSD/CVC). Data from the 54 patients who completed the trial show a reduced infection rate (positive tip culture) in the SSD/CVC group (4 out of 28) compared to the STD/CVC group (10 out of 26) (P < 0.05). In addition, the new Fibrin Analysing System (FAS) brush was evaluated and used to determine the presence of infection in all the CVCs (STD/CVC and SSD/CVC combined, n = 54) at day 3 (i.e. early warning of CVC colonization/infection) and at the time of removal of the CVC. The FAS brush was able to detect an infected CVC on only one occasion on day 3 out of the 14 CVC tips which were later found to be colonized/infected at the time of removal. The sensitivity of the FAS brush in detecting colonized/infected CVCs at the time of CVC removal compared with CVC tip culture was 21% with a specificity of 100%. These findings would currently not support the routine use of the FAS brush in determining CVC infection/colonization.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8805887     DOI: 10.1177/0310057X9602400305

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  10 in total

1.  The relationship between methodological trial quality and the effects of impregnated central venous catheters.

Authors:  Christine Geffers; Irina Zuschneid; Tim Eckmanns; Henning Rüden; Petra Gastmeier
Journal:  Intensive Care Med       Date:  2003-02-08       Impact factor: 17.440

Review 2.  Anti-infective-treated central venous catheters: a systematic review of randomized controlled trials.

Authors:  B S Niël-Weise; T Stijnen; P J van den Broek
Journal:  Intensive Care Med       Date:  2007-10-17       Impact factor: 17.440

3.  Clinical and Regulatory Considerations for Central Venous Catheters for Hemodialysis.

Authors:  Douglas M Silverstein; Scott O Trerotola; Timothy Clark; Garth James; Wing Ng; Amy Dwyer; Marius C Florescu; Roman Shingarev; Stephen R Ash
Journal:  Clin J Am Soc Nephrol       Date:  2018-10-11       Impact factor: 8.237

4.  Antimicrobial impregnated catheters in the prevention of catheter-related bloodstream infection in hospitalized patients.

Authors:  Sarah K Wassil; Catherine M Crill; Stephanie J Phelps
Journal:  J Pediatr Pharmacol Ther       Date:  2007-04

5.  Chlorhexidine and silver-sulfadiazine coated central venous catheters in haematological patients--a double-blind, randomised, prospective, controlled trial.

Authors:  Torben Ostendorf; Andrea Meinhold; Christoph Harter; Hans Salwender; Gerlinde Egerer; Heinrich K Geiss; Antony D Ho; Hartmut Goldschmidt
Journal:  Support Care Cancer       Date:  2005-04-16       Impact factor: 3.603

6.  The Role of Intravascular Devices in Sepsis.

Authors:  Christopher J. Crnich; Dennis G. Maki
Journal:  Curr Infect Dis Rep       Date:  2001-12       Impact factor: 3.725

Review 7.  New technologies to prevent intravascular catheter-related bloodstream infections.

Authors:  L A Mermel
Journal:  Emerg Infect Dis       Date:  2001 Mar-Apr       Impact factor: 6.883

Review 8.  Catheter impregnation, coating or bonding for reducing central venous catheter-related infections in adults.

Authors:  Nai Ming Lai; Nathorn Chaiyakunapruk; Nai An Lai; Elizabeth O'Riordan; Wilson Shu Cheng Pau; Sanjay Saint
Journal:  Cochrane Database Syst Rev       Date:  2016-03-16

9.  Impact of catheter antimicrobial coating on species-specific risk of catheter colonization: a meta-analysis.

Authors:  Aleksey Novikov; Manuel Y Lam; Leonard A Mermel; Anna L Casey; Tom S Elliott; Peter Nightingale
Journal:  Antimicrob Resist Infect Control       Date:  2012-12-03       Impact factor: 4.887

10.  Can a new antiseptic agent reduce the bacterial colonization rate of central venous lines in post-cardiac surgery patients?

Authors:  Fardin Yousefshahi; Khashayar Azimpour; Mohammad Ali Boroumand; Mahdi Najafi; Khosro Barkhordari; Mitra Vaezi; Nahid Rouhipour
Journal:  J Tehran Heart Cent       Date:  2013-04-28
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.