Literature DB >> 880089

[Etiopathogenesis of loosening after total hip replacement (author's transl)].

A Rütt.   

Abstract

We analyzed 30 cases of loosening of different hip-totalendoprotheses (Weber-Huggler, Müller-Charnley, McKee-Ferrar and Brunswick), intraoperative known as aseptic loosening. Especially is shown that also by those protheses with a part of polyäthylen there is the same histological picture as by those protheses of Weber-Huggler with the head of polyester: "the aggressive Granuloma". There is only a gradually difference and the "maligne Osteolysis" was not so excessive.

Entities:  

Mesh:

Year:  1977        PMID: 880089     DOI: 10.1007/bf00415094

Source DB:  PubMed          Journal:  Arch Orthop Unfallchir        ISSN: 0003-9330


  7 in total

1.  [Loosening of the acetabular implant after replacement of the hip-joint due to age-related loss of bone structure (author's transl)].

Authors:  K J Münzenberg; R Dennert
Journal:  Z Orthop Ihre Grenzgeb       Date:  1975-10

2.  [Therapeutic approaches to implant loosening in total hip arthroplasty (author's transl)].

Authors:  A N Witt; M H Hackenbroch
Journal:  Z Orthop Ihre Grenzgeb       Date:  1976-06

3.  [Clinical problems after the use of polyestercomponents in total hip replacement (author's transl)].

Authors:  B Rosemeyer; W Pförringer
Journal:  Arch Orthop Unfallchir       Date:  1976-06-18

4.  [Complications after total hip replacement (author's transl)].

Authors:  K P Schulitz; H O Dustmann
Journal:  Arch Orthop Unfallchir       Date:  1976-06-18

5.  [Experience with poly-ester as a component of the rotation total prosthesis for the hip-joint (author's transl)].

Authors:  B G Weber; G Stühmer; M Semlitsch
Journal:  Z Orthop Ihre Grenzgeb       Date:  1974-10

6.  [Mechanics and type of prosthesis. Biomechanical considerations on the problem of clearance of hip prostheses (author's transl)].

Authors:  M Jäger; M Ungethüm
Journal:  MMW Munch Med Wochenschr       Date:  1976-05-28

7.  [Further experiences with total hip arthroplasty. Clinical and roentgenographic results after 3--6 years following implantation (author's transl)].

Authors:  M H Hackenbroch; H Bruns; R Holbe; H Lechleuthner
Journal:  Arch Orthop Unfallchir       Date:  1976-03-26
  7 in total
  3 in total

1.  Computer-aided manufacture of individual endoprostheses. Preliminary communication.

Authors:  G Aldinger; A Fischer; B Kurtz
Journal:  Arch Orthop Trauma Surg       Date:  1983

2.  An analysis of 119 loosenings in total hip endoprostheses.

Authors:  P Bösch; H Kristen; K Zweymüller
Journal:  Arch Orthop Trauma Surg       Date:  1980

Review 3.  Results of alloarthroplasty of the hip joint.

Authors:  W Oberthaler; R Bauer; K Sattler
Journal:  Arch Orthop Trauma Surg       Date:  1980
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.