Literature DB >> 8800215

The effect of wheelchair handrim tube diameter on propulsion efficiency and force application (tube diameter and efficiency in wheelchairs).

M L van der Linden1, L Valent, H E Veeger, L H van der Woude.   

Abstract

To determine the optimum tube diameter of a standard handrim-propelled wheelchair, the effect of tube size and shape on physiological and kinetic parameters was studied. Six able-bodied male subjects performed two tests on a wheelchair ergometer. Tests were performed against work loads comparable to every day use and with two different handrim tube diameters, a handrim with an oval 25 by 30 mm diameter (LR) and one with an 18 mm diameter (SR). The large tube diameter (LR) yielded slightly but significantly lower values for the physiological parameters. Gross mechanical efficiency was on average 7% for the LR and 6.3% for the SR. No significant results were found for force application parameters related to the direction of the applied force or the torque by the hand onto the handrim surface. As technique parameters could not explain the higher mechanical efficiency (ME) when using the LR, it is suggested that hand grip constraints in the push phase (finger flexor activity) might be responsible. Another possible explanation is that with a better hand grip using LR, less stabilization by the larger muscle groups at the elbow and shoulder is needed. The measured technique parameters seem to be determined by geometric constraints of the arm and shoulder. The technique requirements resulting from the forced trajectory of the propulsion movement are also likely to determine the technique parameters. Regarding the low mechanical efficiency of handrim propulsion, which is partly caused by the forced unfavorable trajectory of the hand, an alternative propulsion mechanism is suggested.

Mesh:

Year:  1996        PMID: 8800215     DOI: 10.1109/86.536767

Source DB:  PubMed          Journal:  IEEE Trans Rehabil Eng        ISSN: 1063-6528


  5 in total

Review 1.  The ergonomics of wheelchair configuration for optimal performance in the wheelchair court sports.

Authors:  Barry S Mason; Lucas H V van der Woude; Victoria L Goosey-Tolfrey
Journal:  Sports Med       Date:  2013-01       Impact factor: 11.136

2.  Measurement of hand/handrim grip forces in two different one arm drive wheelchairs.

Authors:  Anne Mandy; Lucy Redhead; Jon Michaelis
Journal:  Biomed Res Int       Date:  2014-06-19       Impact factor: 3.411

3.  How Was Studied the Effect of Manual Wheelchair Configuration on Propulsion Biomechanics: A Systematic Review on Methodologies.

Authors:  Capucine Fritsch; Yoann Poulet; Joseph Bascou; Patricia Thoreux; Christophe Sauret
Journal:  Front Rehabil Sci       Date:  2022-05-02

4.  The effects of rear-wheel camber on the kinematics of upper extremity during wheelchair propulsion.

Authors:  Chung-Ying Tsai; Chien-Ju Lin; Yueh-Chu Huang; Po-Chou Lin; Fong-Chin Su
Journal:  Biomed Eng Online       Date:  2012-11-22       Impact factor: 2.819

Review 5.  Aspects of manual wheelchair configuration affecting mobility: a review.

Authors:  Fausto Orsi Medola; Valeria Meirelles Carril Elui; Carla da Silva Santana; Carlos Alberto Fortulan
Journal:  J Phys Ther Sci       Date:  2014-02-28
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.