Literature DB >> 8800151

Effects of oxygen, positive end-expiratory pressure, and carbon dioxide on oxygen delivery in an animal model of the univentricular heart.

C J Riordan1, F Randsbeck, J H Storey, W D Montgomery, W P Santamore, E H Austin.   

Abstract

OBJECTIVE: Respiratory manipulations are a mainstay of therapy for infants with a univentricular heart, but until recently little experimental information has been available to guide their use. We used an animal model of a univentricular heart to characterize the physiologic effects of a number of commonly used ventilatory treatments, including altering inspired oxygen tension, adding positive end-expiratory pressure, and adding supplemental carbon dioxide to the ventilator circuit.
RESULTS: Lowering inspired oxygen tension decreased the ratio of pulmonary to systemic flow. This ratio was 1.29 +/- 0.08 at an inspired oxygen tension of 100%, 0.61 +/- 0.09 at an inspired oxygen tension of 21%, and 0.42 +/- 0.09 at an inspired oxygen tension of 15% (p < 0.05 compared with an inspired oxygen tension of 100% and a positive end-expiratory pressure of 0 cm H2O). High-concentration supplemental carbon dioxide (carbon dioxide tension of 80 to 90 mm Hg) added to the ventilator circuit decreased inspired oxygen tension from 1.29 +/- 0.11 to 0.42 +/- 0.12 (p < 0.05 compared with baseline). A mixture of 95% oxygen and 5% carbon dioxide (carbon dioxide tension of 50 to 60 mm Hg) did not decrease the pulmonary/systemic flow ratio significantly. All three types of interventions influenced systemic oxygen delivery, which was a function of the pulmonary/systemic flow ratio. As the pulmonary/systemic flow ratio decreased from initially high levels (greater than 1), oxygen delivery first increased and reached an optimum at a flow ratio slightly less than 1. As the pulmonary/systemic flow ratio decreased further, below 0.7, oxygen delivery decreased. The ability of systemic arterial and venous oxygen saturations to predict the pulmonary/systemic flow ratio was examined. Venous oxygen saturation correlated well with both pulmonary/systemic flow ratio and systemic oxygen delivery, whereas arterial oxygen saturation did not accurately predict either pulmonary/systemic flow ratio or oxygen delivery.
CONCLUSION: This model demonstrated the value of estimating the pulmonary/systemic flow ratio before initiating therapy. When the initial ratio was greater than about 0.7, interventions that decreased the ratio increased oxygen delivery and were beneficial. When the initial pulmonary/systemic flow ratio was below 0.7, interventions that decreased the ratio decreased oxygen delivery and were detrimental. We conclude by presenting a framework to guide therapy based on the combination of arterial and venous oxygen saturations and the estimate of the pulmonary/systemic flow ratio that they provide.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8800151     DOI: 10.1016/s0022-5223(96)70047-8

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  6 in total

Review 1.  Balancing a single-ventricle circulation: 'physiology to therapy'.

Authors:  Rohan Magoon; Neeti Makhija; Surendra Kumar Jangid
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2020-01-02

2.  Supplemental nitrogen inhalation therapy in very low-birth-weight infants with patent ductus arteriosus.

Authors:  T Tan; N Mizobe; H Sugiyama; Y Maeda; A Naitou; K Kodera; T Sato; S Nakazawa
Journal:  Pediatr Cardiol       Date:  2005 Nov-Dec       Impact factor: 1.655

Review 3.  Hypoplastic left heart syndrome: current considerations and expectations.

Authors:  Jeffrey A Feinstein; D Woodrow Benson; Anne M Dubin; Meryl S Cohen; Dawn M Maxey; William T Mahle; Elfriede Pahl; Juan Villafañe; Ami B Bhatt; Lynn F Peng; Beth Ann Johnson; Alison L Marsden; Curt J Daniels; Nancy A Rudd; Christopher A Caldarone; Kathleen A Mussatto; David L Morales; D Dunbar Ivy; J William Gaynor; James S Tweddell; Barbara J Deal; Anke K Furck; Geoffrey L Rosenthal; Richard G Ohye; Nancy S Ghanayem; John P Cheatham; Wayne Tworetzky; Gerard R Martin
Journal:  J Am Coll Cardiol       Date:  2012-01-03       Impact factor: 24.094

Review 4.  [Anesthesia in children and adolescents with congenital heart defects].

Authors:  T Baehner; O Boehm; M Kliemann; I Heinze; J Breuer; A Hoeft; G Baumgarten; P Knuefermann
Journal:  Anaesthesist       Date:  2015-06       Impact factor: 1.041

5.  A Novel Technique for the Administration of Sub-Ambient Oxygen in the Operating Room.

Authors:  Asad A Khawaja; Marco Corridore; Joseph D Tobias
Journal:  Cardiol Res       Date:  2017-10-27

6.  3D Simulation Analysis of Central Shunt in Patient-Specific Hemodynamics: Effects of Varying Degree of Pulmonary Artery Stenosis and Shunt Diameters.

Authors:  Jiawei Liu; Haiyun Yuan; Neichuan Zhang; Xiangyu Chen; Chengbin Zhou; Meiping Huang; Qifei Jian; Jian Zhuang
Journal:  Comput Math Methods Med       Date:  2020-02-14       Impact factor: 2.238

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.