Literature DB >> 8799628

Interlaboratory variation of GHb assays in Victoria, Australia.

R E Gilbert1, I Goodall, V Young, G Jerums.   

Abstract

OBJECTIVE: To determine the extent of interlaboratory variation and accuracy in the measurement of glycated hemoglobin (GHb). RESEARCH DESIGN AND METHODS: All laboratories that measure glycated hemoglobin in the State of Victoria, Australia, were invited to participate, and positive responses were received from 27 to 30 laboratories. An aliquot of blood drawn from three patients with diabetes and varied glycemia and from one nondiabetic subject was sent to each participating laboratory. Distribution of results was analyzed according to the reported results and their variance from an assigned reference value and were expressed as differing from this latter value as percentage bias and in absolute terms. A bias > or = 10% or an absolute difference of > or = 1% HbA1c from the reference value was considered significant.
RESULTS: Reported results for the same blood sample ranged from 4.1 to 5.8%, 5.1 to 8.2%, 6.7 to 9.3%, and 10.1 to 14.7% for the specimens from the nondiabetic subject and the diabetic patients with good, moderate, and poor glycemic control, respectively. The proportion of laboratories with results that differed by > or = 10% bias from the reference value were 39% (12 of 30), 29% (9 of 30), 16% (5 of 30), and 32% (10 of 30), and the proportion reporting results that differed by > or = 1% HbA1c in absolute terms from the reference values were 3% (1 of 30), 6% (2 of 30), 16% (5 of 30), and 23% (7 of 30) for the specimens from the nondiabetic subject and the diabetic patients with good, moderate, and poor glycemic control, respectively.
CONCLUSIONS: A substantial degree of interlaboratory variation for GHb measurement exists in Victoria, Australia. This may lead to difficulties in interpretation when GHb is assayed by different laboratories in the same patient over time. Interlaboratory standardization may be achievable by calibration to a standard assigned by a reference laboratory and distributed to all laboratories measuring GHb.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8799628     DOI: 10.2337/diacare.19.7.730

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  2 in total

1.  HbA1c standardisation destination--global IFCC Standardisation. How, why, where and when--a tortuous pathway from kit manufacturers, via inter-laboratory lyophilized and whole blood comparisons to designated national comparison schemes.

Authors:  Ian Goodall
Journal:  Clin Biochem Rev       Date:  2005-02

2.  Diabetes in rural towns: effectiveness of continuing education and feedback for healthcare providers in altering diabetes outcomes at a population level: protocol for a cluster randomised controlled trial.

Authors:  Christine L Paul; Leon Piterman; Jonathan Shaw; Catherine Kirby; Robert W Sanson-Fisher; Mariko L Carey; Jennifer Robinson; Patrick McElduff; Isaraporn Thepwongsa
Journal:  Implement Sci       Date:  2013-03-13       Impact factor: 7.327

  2 in total