Literature DB >> 8797412

Reproducibility of cardiopulmonary exercise parameters in patients with valvular heart disease.

G Lehmann1, K Kölling.   

Abstract

STUDY
OBJECTIVES: To determine the degree of reproducibility of exercise parameters in patients with chronic heart failure. Parameters such as treadmill walking time (TWT), oxygen uptake (Vo2), heart rate, oxygen pulse, minute ventilation (VE) ventilatory equivalents for oxygen uptake (VE/Vo2) and carbon dioxide output (Vco2), and respiratory quotient at both anaerobic threshold (AT) and peak exercise (PE) each were assessed.
DESIGN: Using the Naughton-Weber protocol, two repeated cardiopulmonary treadmill exercise tests were performed after detailed instructions prior to the first test and on strict adherence to standardized investigational conditions, viz, at the same time of day and at the same ambient temperature, receiving constant medication, and while in a 12-h fasting state. PATIENTS: The studies were carried out in 17 patients with chronic heart failure due to valvular heart disease considered candidates for intervention because of symptoms. According to Weber's classification of functional capacity, 10 patients were in class A (Vo2 max > 20 mL O2/min/kg), 5 patients were in class B (16 to 20 mL O2/min/kg), and the remaining 2 were in class C (10 to 16 mL O2/min/kg). MEASUREMENTS: Parameters assessed were TWT, Vo2, heart rate, oxygen pulse, VE and ventilatory equivalents for oxygen (VE/Vo2) and carbon dioxide (VE/Vco2) both at AT and at PE. To reflect reproducibility, correlation coefficients (r) were calculated.
RESULTS: An excellent reproducibility was found for TWT (r = 0.963, p < 0.0001), Vo2 at AT in percent of predicted Vo2max (r = 0.984, p < 0.0001), Vo2 at PE (r = 0.996, p < 0.0001), heart rate at AT (r = 0.943, p < 0.0001) and at PE (r = 0.928, p < 0.0001), oxygen pulse at AT (r = 0.980, p < 0.001) and at PE (r = 0.991, p < 0.0001), VE at AT (r = 0.949, p < 0.0001) and at PE (r = 0.912, p < 0.0001) as well as VE/Vo2 at AT (r = 0.942, p < 0.0001) and at PE (r = 0.781, p < 0.0002) and VE/Vco2 at AT (r = 0.995, p < 0.0001) and at PE (r = 0.943, p < 0.0001), respectively.
CONCLUSIONS: On adherence to standardized conditions, an excellent reproducibility existed for TWT, Vo2 (reflecting cardiac output), ventilation, and heart rate as well as derived parameters, rendering cardiopulmonary exercise testing a reliable means of quantification of heart failure as a prerequisite for enabling diagnostic or therapeutic decisions.

Entities:  

Mesh:

Year:  1996        PMID: 8797412     DOI: 10.1378/chest.110.3.685

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  6 in total

1.  Peak oxygen uptake. Myth and truth about an internationally accepted reference value.

Authors:  T Meyer; J Scharhag; W Kindermann
Journal:  Z Kardiol       Date:  2005-04

2.  Maximal aerobic capacity and the oxygen uptake efficiency slope as predictors of large artery stiffness in apparently healthy subjects.

Authors:  Ross Arena; James A Arrowood; Ding-Yu Fei; Shirley Helm; Kenneth A Kraft
Journal:  J Cardiopulm Rehabil Prev       Date:  2009 Jul-Aug       Impact factor: 2.081

3.  Inability of myalgic encephalomyelitis/chronic fatigue syndrome patients to reproduce VO₂peak indicates functional impairment.

Authors:  Betsy A Keller; John Luke Pryor; Ludovic Giloteaux
Journal:  J Transl Med       Date:  2014-04-23       Impact factor: 5.531

4.  Cardiopulmonary Exercise Test Methodology for Assessing Exertion Intolerance in Myalgic Encephalomyelitis/Chronic Fatigue Syndrome.

Authors:  Staci Stevens; Chris Snell; Jared Stevens; Betsy Keller; J Mark VanNess
Journal:  Front Pediatr       Date:  2018-09-04       Impact factor: 3.418

5.  Reproducibility of the self-controlled six-minute walking test in heart failure patients.

Authors:  Guilherme Veiga Guimarães; Vitor Oliveira Carvalho; Edimar Alcides Bocchi
Journal:  Clinics (Sao Paulo)       Date:  2008-04       Impact factor: 2.365

6.  A Brief Questionnaire to Assess Post-Exertional Malaise.

Authors:  Joseph Cotler; Carly Holtzman; Catherine Dudun; Leonard A Jason
Journal:  Diagnostics (Basel)       Date:  2018-09-11
  6 in total