Literature DB >> 8796730

Magnetic resonance lymphography in rats: effects of muscular activity and hyperthermia on the lymph node uptake of intravenously injected superparamagnetic iron oxide particles.

V Elste1, S Wagner, M Taupitz, D Pfefferer, M Kresse, B Hamm, R Berg, K J Wolf, W Semmler.   

Abstract

RATIONALE AND
OBJECTIVES: We investigated the influence of muscular activity and regional body temperature changes on the accumulation of intravenously (i.v.) administered, dextran-coated superparamagnetic iron oxide (SPIO) particles in the lymph nodes of rats.
METHODS: Four groups of rats (N = 21) were used. Five rats were allowed to move freely after i.v. contrast administration (group 1). In another five rats, muscular inactivity (group 2) was induced during i.v. injection of SPIO particles and for up to 2 hr thereafter by anesthesia. In seven rats (likewise anesthetized), the contrast agent was administered while the extremities of one side of the body were warmed in a water bath for 2 hr (group 3). The rats in groups 1-3 received 100 mumol Fe/kg of the contrast agent. Four rats not given SPIO particles served as the control group (group 4). The lymph nodes of all animals were removed 24 hr after SPIO administration and were embedded in an agar matrix for magnetic resonance imaging at 1.5 T using a proton-density-weighted spin-echo (PD-SE) sequence and a T2*-weighted gradient-recalled echo (T2* GRE) sequence.
RESULTS: Signal loss varied widely among the different lymph nodes in group 1. A pronounced signal reduction was observed in the mesenteric (PD-SE = 20 +/- 6%, T2* GRE = 55 +/- 19%), iliac (PD-SE = 13 +/- 13%, T2* GRE = 44 +/- 24%), and popliteal (PD-SE = 24 +/- 7%, T2* GRE = 70 +/- 11%) lymph nodes and only a moderate reduction in the mandibular (PD-SE = 4 +/- 7%, T2* GRE = 42 +/- 15%), axillary (PD-SE = 0 +/- 4%, T2* GRE = 8 +/- 7%), and inguinal (PD-SE = 5 +/- 5%, T2* GRE = 34 +/- 18%) lymph nodes. The least pronounced signal loss occurred in the peripheral lymph nodes of group 2, ranging from 0 +/- 3% for PD-SE sequences and 10 +/- 11% for T2* GRE sequences to 13 +/- 15% for PD-SE sequences and 41 +/- 19% for T2* GRE sequences. In group 3, the uptake of contrast material in the peripheral lymph nodes of the hyperthermal side was significantly more pronounced than on the contralateral side (p < .01), and the contrast agent was distributed more evenly to the different lymph node groups than in group 1.
CONCLUSION: Muscular activity and regional hyperthermia markedly influence the accumulation of SPIO particles in different lymph node groups in rats. These findings must be considered in preclinical studies and in the clinical administration of MR lymphography.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8796730     DOI: 10.1016/s1076-6332(96)80193-0

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  1 in total

1.  Dextran gadolinium complexes as contrast agents for magnetic resonance imaging to sentinel lymph nodes.

Authors:  Guo-Ping Yan; Wei Xu; Lian Yang; Liang Li; Fan Liu; Qing-Zhong Guo
Journal:  Pharm Res       Date:  2010-06-18       Impact factor: 4.200

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.