Literature DB >> 879604

Use of expanded polytetrafluoroethylene grafts for vascular access in hemodialysis: laboratory and clinical evaluation.

M P Elliott, A B Gazzaniga, J M Thomas, N J Haiduc, S M Rosen.   

Abstract

Vascular access for chronic hemodialysis has evolved considerably over the past 10 years with development of vascular substitutes. The bovine heterograft is the choice of most dialysis centers when a subcutaneous conduit is needed in lieu of an in situ arteriovenous fistula. Bovine grafts have solved some problems, but further improvement in blood access prostheses is needed. Polytetrafluoroethylene (PTFE) grafts were evaluated in a laboratory and clinical study. In animals, PTFE proved to be satisfactory for fistula construction based on patency, incorporation into tissue, and ease of puncture. Ten patients underwent 11 vascular access procedures using PTFE grafts as a conduit. There were no technical operative complications. One graft was occluded by extravasation during dialysis and flow could not be restored. Otherwise, all grafts are patent 9 to 18 months postoperatively. Grafts of 8.0 mm in diameter have not given desirable flow rates, whereas 6.0 mm grafts have. Prolonged bleeding from puncture has been a problem in some cases. Otherwise, PTFE appears to be a satisfactory conduit for hemodialysis vascular access.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 879604

Source DB:  PubMed          Journal:  Am Surg        ISSN: 0003-1348            Impact factor:   0.688


  6 in total

Review 1.  Vascular access for hemodialysis: A perpetual challenge.

Authors:  Mariana Murea; Randolph L Geary; Ross P Davis; Shahriar Moossavi
Journal:  Semin Dial       Date:  2019-06-17       Impact factor: 3.455

2.  Non-dialysis vascular access.

Authors:  E A Kiely; T O'Brien; J A O'Donnell
Journal:  Ir J Med Sci       Date:  1984-10       Impact factor: 1.568

Review 3.  Neointimal hyperplasia associated with synthetic hemodialysis grafts.

Authors:  Li Li; Christi M Terry; Yan-Ting E Shiu; Alfred K Cheung
Journal:  Kidney Int       Date:  2008-07-30       Impact factor: 10.612

Review 4.  Progress and challenges in macroencapsulation approaches for type 1 diabetes (T1D) treatment: Cells, biomaterials, and devices.

Authors:  Shang Song; Shuvo Roy
Journal:  Biotechnol Bioeng       Date:  2016-01-04       Impact factor: 4.530

5.  Dacron velour arteriovenous fistula for hemodialysis access.

Authors:  S M Lindenauer; R Williams
Journal:  Ann Surg       Date:  1981-01       Impact factor: 12.969

6.  Timing of the first cannulation and survival of arteriovenous grafts in hemodialysis patients: a multicenter retrospective cohort study.

Authors:  Su-Ju Lin; Shu-Chen Chang; Chun-Wu Tung; Yung-Chien Hsu; Ya-Hsueh Shih; Yi-Ling Wu; Tse-Chih Chou; Chun-Liang Lin
Journal:  Ren Fail       Date:  2021-12       Impact factor: 2.606

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.