Literature DB >> 8794930

Liquid chromatography/chemical reaction interface mass spectrometry as an alternative to radioisotopes for quantitative drug metabolism studies.

C A Goldthwaite1, F Y Hsieh, S W Womble, B J Nobes, I A Blair, L J Klunk, R F Mayol.   

Abstract

Chemical reaction interface mass spectrometry (CRIMS) was coupled on-line with HPLC using a Vestec particle beam interface. A helium-assisted nebulizer provided added stability with no loss in accuracy or precision as compared to the thermospray nebulizer at flow rates of up to 1.0 mL/min using isocratic conditions. However, mass spectral response was found to be solvent-dependent for both the helium-assisted and thermospray nebulizers. Postcolumn solvent addition of methanol eliminated solvent-dependent decreases in mass spectral response. This allowed gradient HPLC elutions to be performed. Under these conditions, the flow of solvent into the particle beam interface was 2.5 mL/min, so a conventional thermospray nebulizer had to be used instead of the helium-assisted nebulizer. Experiments were conducted with the antianxiety agent buspirone in order to validate the methodology. Metabolites from in vitro incubations of [15N]/[14C]buspirone with rat liver slices were analyzed by gradient LC/CRIMS and by gradient LC/[14C] radioactivity counting. The response from LC/CRIMS analysis for individual metabolites was then compared with that obtained by LC/[14C] radioactivity counting. An excellent correlation was observed between the two methods for metabolites with quite different HPLC characteristics. Thus, gradient LC/CRIMS in combination with stable isotopes provides an alternative to using radioisotopes for carrying out drug metabolism studies.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8794930     DOI: 10.1021/ac960044j

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

Review 1.  Mass spectrometry innovations in drug discovery and development.

Authors:  D I Papac; Z Shahrokh
Journal:  Pharm Res       Date:  2001-02       Impact factor: 4.200

Review 2.  Clinical pharmacokinetics and pharmacodynamics of buspirone, an anxiolytic drug.

Authors:  I Mahmood; C Sahajwalla
Journal:  Clin Pharmacokinet       Date:  1999-04       Impact factor: 6.447

3.  Flow injection with chemical reaction interface-isotope ratio mass spectrometry: an alternative to off-line combustion for detecting low levels of enriched 13C in mass balance studies.

Authors:  P Chen; Y Teffera; G E Black; F P Abramson
Journal:  J Am Soc Mass Spectrom       Date:  1999-02       Impact factor: 3.109

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.