Literature DB >> 8788059

Quantitative in vivo measurements using microdialysis on-line with capillary zone electrophoresis.

M W Lada1, R T Kennedy.   

Abstract

A system which couples microdialysis with capillary zone electrophoresis (CZE) on-line is used to monitor ascorbate and lactate in the caudate nucleus of rat brain. On-line interface of microdialysis probe and electrophoresis capillary, along with the high mass sensitivity of CZE, allows the probe to be operated at flow rates as low as 40 nl/min. Under these conditions, the relative recovery is nearly 100% and quantitative monitoring is possible. The microscale system also facilitates calibration by the low flow rate method. In spite of the low flow rate, temporal resolution in the 45-125 s range is possible for these compounds. The system is demonstrated by observing changes in ascorbate due to infusions of elevated K+ through the dialysis probe and systemic injections of amphetamine and an anesthetic (ketamine/xylazine/acepromazine mixture). Lactate is monitored in response to elevated K+ infusions.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8788059     DOI: 10.1016/0165-0270(95)00104-2

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  5 in total

Review 1.  Capillary electrophoresis in pharmaceutical analysis.

Authors:  L A Holland; N P Chetwyn; M D Perkins; S M Lunte
Journal:  Pharm Res       Date:  1997-04       Impact factor: 4.200

Review 2.  A Review on Microdialysis Calibration Methods: the Theory and Current Related Efforts.

Authors:  Chun Min Kho; Siti Kartini Enche Ab Rahim; Zainal Arifin Ahmad; Norazharuddin Shah Abdullah
Journal:  Mol Neurobiol       Date:  2016-05-17       Impact factor: 5.590

3.  Evaluation of an osmotic pump for microdialysis sampling in an awake and untethered rat.

Authors:  Joshua D Cooper; Kathleen E Heppert; Malonne I Davies; Susan M Lunte
Journal:  J Neurosci Methods       Date:  2006-10-31       Impact factor: 2.390

4.  Online photolytic optical gating of caged fluorophores in capillary zone electrophoresis utilizing an ultraviolet light-emitting diode.

Authors:  Elyssia S Gallagher; Troy J Comi; Kevin L Braun; Craig A Aspinwall
Journal:  Electrophoresis       Date:  2012-08-22       Impact factor: 3.535

Review 5.  Recent trends in microdialysis sampling integrated with conventional and microanalytical systems for monitoring biological events: a review.

Authors:  Pradyot Nandi; Susan M Lunte
Journal:  Anal Chim Acta       Date:  2009-08-03       Impact factor: 6.558

  5 in total