Literature DB >> 8783460

Observer variability in volumetric blood flow measurements in leg arteries using duplex ultrasound.

S T Hussain1, R E Smith, R F Wood, M Bland.   

Abstract

Duplex ultrasound volumetric flow measurements have not found a major clinical use because of variability caused by errors in estimating cross-sectional area (CSA) and in measuring time averaged mean velocity (TAMeV). We determined inter- and intraobserver variation in volumetric blood flow measured at rest in the common femoral artery (CFA) and its main branches, the superficial femoral (SFA) and profunda femoris (PFA) arteries, in 20 normal subjects. The product of TAMeV and CSA was taken as volumetric flow. The coefficient of variation of TAMeV was consistently greater than that of CSA. Interobserver variation for blood flow (16.2%, 20.2% and 40.3% for CFA, SFA and PFA, respectively) was larger than intraobserver variation (13.0%, 15.1%, 21.2%). In conclusion, these data define the minimum changes in VQ that can be realistically detected and indicate that, with modern duplex Doppler equipment, volumetric flow can be used as a reliable haemodynamic measure for monitoring patients before and after surgical or radiological intervention.

Entities:  

Mesh:

Year:  1996        PMID: 8783460     DOI: 10.1016/0301-5629(95)02050-0

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  9 in total

Review 1.  Blood flow measurements in lower limb arteries using duplex ultrasound.

Authors:  S T Hussain
Journal:  Ann R Coll Surg Engl       Date:  1997-09       Impact factor: 1.891

2.  Effects of dynamic arm and leg exercise on muscle sympathetic nerve activity and vascular conductance in the inactive leg.

Authors:  Connor J Doherty; Trevor J King; Anthony V Incognito; Jordan B Lee; Andrew D Shepherd; Joseph A Cacoilo; Joshua T Slysz; Jamie F Burr; Philip J Millar
Journal:  J Appl Physiol (1985)       Date:  2019-06-27

3.  Image-derived input function in dynamic human PET/CT: methodology and validation with 11C-acetate and 18F-fluorothioheptadecanoic acid in muscle and 18F-fluorodeoxyglucose in brain.

Authors:  Etienne Croteau; Eric Lavallée; Sébastien M Labbe; Laurent Hubert; Fabien Pifferi; Jacques A Rousseau; Stephen C Cunnane; André C Carpentier; Roger Lecomte; François Bénard
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-05-02       Impact factor: 9.236

4.  Exercise-induced arterial adaptations in elite judo athletes.

Authors:  Panagiotis Karagounis; Maria Maridaki; Xenofon Papaharalampous; Giorgos Prionas; Panagiotis Baltopoulos
Journal:  J Sports Sci Med       Date:  2009-09-01       Impact factor: 2.988

5.  Accuracy of volumetric flow rate measurements: an in vitro study using modern ultrasound scanners.

Authors:  Kenneth Hoyt; Felix A Hester; Randall L Bell; Mark E Lockhart; Michelle L Robbin
Journal:  J Ultrasound Med       Date:  2009-11       Impact factor: 2.153

6.  Physiological aspects of the determination of comprehensive arterial inflows in the lower abdomen assessed by Doppler ultrasound.

Authors:  Takuya Osada
Journal:  Cardiovasc Ultrasound       Date:  2012-03-26       Impact factor: 2.062

7.  Effect of saline injection mixing on accuracy of conductance lumen sizing of peripheral vessels.

Authors:  Hyo Won Choi; Benjamin Jansen; David Birrer; Ghassan S Kassab
Journal:  PLoS One       Date:  2013-09-13       Impact factor: 3.240

8.  Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines.

Authors:  Ji Young Hwang
Journal:  Ultrasonography       Date:  2017-01-18

9.  Variability of Lower Limb Artery Systolic-Diastolic Velocities in Futsal Athletes and Non-Athletes: Evaluation by Arterial Doppler Ultrasound.

Authors:  Pedro Duarte-Mendes; Rui Paulo; Patrícia Coelho; Francisco Rodrigues; Vasco Marques; Sónia Mateus
Journal:  Int J Environ Res Public Health       Date:  2020-01-16       Impact factor: 3.390

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.