Literature DB >> 8782951

Subclavian artery injury caused by a screw in a clavicular compression plate.

B Johnson1, P Thursby.   

Abstract

A 22-year-old man presented with left-arm ischaemia, 22 months after placement of a clavicular compression plate for a fractured left clavicle. Digital subtraction angiography revealed a distal subclavian artery injury which, during surgery, was found to be caused by a screw in the compression plate. Ligation of the subclavian artery followed by carotid-axillary bypass resulted in a symptom-free left arm.

Entities:  

Mesh:

Year:  1996        PMID: 8782951     DOI: 10.1016/0967-2109(95)00095-x

Source DB:  PubMed          Journal:  Cardiovasc Surg        ISSN: 0967-2109


  8 in total

1.  Patient Position Is Related to the Risk of Neurovascular Injury in Clavicular Plating: A Cadaveric Study.

Authors:  Chaiwat Chuaychoosakoon; Porames Suwanno; Tanarat Boonriong; Sitthiphong Suwannaphisit; Prapakorn Klabklay; Wachirapan Parinyakhup; Korakot Maliwankul; Yada Duangnumsawang; Boonsin Tangtrakulwanich
Journal:  Clin Orthop Relat Res       Date:  2019-12       Impact factor: 4.176

2.  Sonographic assessment of orthopedic hardware impingement on soft tissues of the limbs.

Authors:  R Guillin; S Bianchi
Journal:  J Ultrasound       Date:  2012-01-23

Review 3.  Major neurovascular complications of clavicle fracture surgery.

Authors:  Harry Ds Clitherow; Gregory I Bain
Journal:  Shoulder Elbow       Date:  2014-08-01

4.  Axillary artery pseudoaneurysm after plate osteosynthesis for a clavicle nonunion: A case report and literature review.

Authors:  Gregory I Bain; Ian J Galley; Angus R E Keogh; Adam W Durrant
Journal:  Int J Shoulder Surg       Date:  2010-07

5.  Subclavian artery injury secondary to clavicular plate fixation: a novel operative approach.

Authors:  Kalpa G Perera; Celia Clifford; Lachlan Maddock
Journal:  J Surg Case Rep       Date:  2015-04-15

6.  Dual Motor Drill Continuously Measures Drilling Energy to Calculate Bone Density and Screw Pull-out Force in Real Time.

Authors:  Brian B Gilmer; Sarah D Lang
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2018-09-25

7.  Factors Associated With the Accuracy of Depth Gauge Measurements.

Authors:  Pengcheng Liu; Joanna Xi Xiao; Chen Zhao; Xiaodong Li; Guantong Sun; Fei Yang; Xiaoqing Wang
Journal:  Front Surg       Date:  2022-01-13

Review 8.  Association between screw prominence and vascular complications after clavicle fixation.

Authors:  Harry D S Clitherow; Gregory I Bain
Journal:  Int J Shoulder Surg       Date:  2014-10
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.