Literature DB >> 8779421

Design of a high-precision fraction collector for capillary electrophoresis.

O Müller1, F Foret, B L Karger.   

Abstract

A high-precision fraction collector for capillary electrophoresis has been developed. The device utilizes detection close to the end of the capillary and a sheath liquid at the exit of the capillary, allowing continuous collection (i.e., uninterrupted applied electrical field) of multiple species. The role of the sheath liquid flow rate and position of detection in the column on the collection precision was assessed. Fiber-optic detection at approximately 1 cm before the exit end of the capillary was found effective for precise timing of the collection. Up to 60 fractions of microliter or smaller volumes could be automatically collected into capillaries used as collection vials. The collection capillaries were placed on a cylinder, and a computer-controlled stepping motor aligned the appropriate capillary with the column exit. The effectiveness of the fraction collector was demonstrated in the collection of all 11 fragments of the HaeIII restriction digest of phi X-174 plasmid DNA. Polymerase chain reaction amplification of the 271 and 281 bp fragments revealed an inversion of the size-dependent migration order.

Mesh:

Substances:

Year:  1995        PMID: 8779421     DOI: 10.1021/ac00113a036

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  Quantitative analysis of gene expression by reverse transcription polymerase chain reaction and capillary electrophoresis with laser-induced fluorescence detection.

Authors:  Mark P Richards; Stephen M Poch
Journal:  Mol Biotechnol       Date:  2002-05       Impact factor: 2.695

2.  Facilitating the hyphenation of CIEF and MALDI-MS for two-dimensional separation of proteins.

Authors:  Chang Cheng; Joann J Lu; Xiayan Wang; Jonathan Roberts; Shaorong Liu
Journal:  Electrophoresis       Date:  2010-08       Impact factor: 3.535

3.  A molecular fraction collecting tool for the ABI 310 automated sequencer.

Authors:  Ming-Tseh Lin; Roy G Rich; Royce F Shipley; Michael J Hafez; Li-Hui Tseng; Kathleen M Murphy; Christopher D Gocke; James R Eshleman
Journal:  J Mol Diagn       Date:  2007-10-04       Impact factor: 5.568

4.  Enhanced neuropeptide profiling via capillary electrophoresis off-line coupled with MALDI FTMS.

Authors:  Junhua Wang; Mingming Ma; Ruibing Chen; Lingjun Li
Journal:  Anal Chem       Date:  2008-07-22       Impact factor: 6.986