Literature DB >> 8778634

Interference from duodeno-gastric reflux of 99Tcm radiopharmaceuticals in SPET myocardial perfusion imaging.

G W Middleton1, J H Williams.   

Abstract

Single photon emission tomographic (SPET) myocardial perfusion imaging was performed on 76 patients using 99Tcm-sestamibi (99Tcm-MIBI). Retrospective analysis of the data showed good cardiac uptake and adequate hepatobiliary clearance. However, duodeno-gastric reflux of the activity excreted from the liver and gallbladder was seen in 34% of the studies. This reflux was considered to be severe in 16% of the studies, resulting in interference with the myocardial uptake and requiring three studies to be repeated. In an attempt to minimize interference from duodeno-gastric reflux, a further 86 patients (18 using 99Tcm-MIBI and 68 using 99Tcm-tetrofosmin) were imaged after lying on their right side for 20 min prior to imaging. Good cardiac uptake with adequate hepatobiliary clearance was again achieved. The incidence of duodeno-gastric reflux was significantly lower (P < 0.001), occurring in 22% of studies, while severe reflux occurred in 6% of studies with no studies being repeated. There was no significant difference in the incidence of reflux between the two agents. Duodeno-gastric reflux of 99Tcm-MIBI and 99Tcm-tetrofosmin is common and can result in significant interference with myocardial uptake. It is concluded that having patients lie on their right side for 20 min prior to imaging is a simple and effective method for significantly reducing the likelihood of such interference.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8778634     DOI: 10.1097/00006231-199602000-00004

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  6 in total

1.  Massive left pleural effusion resulting in false-positive myocardial perfusion.

Authors:  Wei-Jen Shih; Todd Justice
Journal:  J Nucl Cardiol       Date:  2005 Jul-Aug       Impact factor: 5.952

2.  Duodenogastroesophageal reflux in a patient with postoperative esophageal cancer shown on Tc-99m tetrofosmin raw data images of dual-isotope gated cardiac SPECT.

Authors:  Wei-Jen Shih; Primo P Milan
Journal:  J Nucl Cardiol       Date:  2004 Jul-Aug       Impact factor: 5.952

3.  Hiatal hernia detected by Tc-99m tetrofosmin SPECT.

Authors:  Gilbert J Zoghbi; Jack Heo; Ami E Iskandrian
Journal:  J Nucl Cardiol       Date:  2003 Nov-Dec       Impact factor: 5.952

4.  The prevalence and significance of increased gastric wall radiotracer uptake in sestamibi myocardial perfusion SPECT.

Authors:  Ali Gholamrezanezhad; Davoud Moinian; Mohammad Eftekhari; Sahar Mirpour; Hadi Hajimohammadi
Journal:  Int J Cardiovasc Imaging       Date:  2006-03-04       Impact factor: 2.357

5.  A novel use for myocardial perfusion scans: diagnosis of bile duct injury.

Authors:  Laura Donahoe; David C Barnes; Ian Alwayn
Journal:  BMJ Case Rep       Date:  2013-08-07

6.  The problem of radiotracer abdominal activity in myocardial perfusion imaging studies.

Authors:  Randall C Thompson
Journal:  J Nucl Cardiol       Date:  2008 Mar-Apr       Impact factor: 3.872