Literature DB >> 8772757

Prevention of recurrent atrial fibrillation with chronic dual-site right atrial pacing.

S Saksena1, A Prakash, M Hill, R B Krol, A N Munsif, P P Mathew, R Mehra.   

Abstract

OBJECTIVES: We investigated 1) the feasibility, safety and efficacy of multisite right atrial pacing for prevention of atrial fibrillation (AF); and 2) the ability of atrial pacing in single- and dual-site modes to increase arrhythmia-free intervals in patients with drug-refractory AF.
BACKGROUND: We recently developed and applied a novel technique of dual-site right atrial pacing in an unselected group of consecutive patients with AF requiring demand pacing. A prospective crossover study design was used to evaluate single- and dual-site right atrial pacing modes.
METHODS: The frequency of AF during the 3 months before pacemaker implantation was analyzed. Consecutive consenting patients underwent insertion of two atrial leads and one ventricular lead with a DDDR pulse generator. Patients were placed in a dual-site pacing mode for the first 3 months and subsequently mode switched to single site pacing for 3 months. Mode switching was repeated at 6-month intervals thereafter.
RESULTS: Atrial pacing resulted in a marked decline in AF recurrences (p < 0.001). During dual-site pacing with an optimal drug regimen, there was no AF recurrence in any patient compared with five recurrences in 12 patients during single-site pacing (p = 0.03). The mean (+/-SD) arrhythmia-free interval before pacing (14 +/- 14 days) was prolonged with dual- (89 +/- 7 days, p < 0.0001) and single-site pacing (76 +/- 27 days, p < 0.0001). Symptomatic AF episodes showed a declining trend during dual- and single-site pacing compared with those during the preimplantation period (p = 0.10). Mean antiarrhythmic drug use for all classes declined from 4 +/- 1.9 drugs before implantation to 1.5 +/- 0.5 (p < 0.01) drugs after implantation. Twelve (80%) of 15 patients remained in atrial paced rhythm at 13 +/- 3 months.
CONCLUSIONS: We conclude that multisite right atrial pacing is feasible, effective and safe for long-term application. Atrial pacing significantly prolongs arrhythmia-free intervals in patients with drug-refractory paroxysmal AF. Dual-site right atrial pacing may offer additional benefits and should be considered either as the primary mode or in patients unresponsive to single-site pacing.

Entities:  

Mesh:

Year:  1996        PMID: 8772757     DOI: 10.1016/0735-1097(96)00232-x

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  44 in total

Review 1.  Developing clinical indication for multisite pacing.

Authors:  L Kappenberger; X Lyon; N Cox; G Girod; J Schlaepfer
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

Review 2.  Lessons learnt from multisite pacing for AF management-technical challenges.

Authors:  R Mehra; B Kaemmerer; S Fitts
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

Review 3.  New devices and hybrid therapies and new devices for treatment of atrial fibrillation.

Authors:  R B Krol; S Saksena; A Prakash
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

4.  [Atrial fibrillation and atrial flutter in congestive heart failure-- non-medication treatment].

Authors:  E Hoffmann; P Nimmermann; S Janko; C Reithmann; K Finkner; T Remp; A Gerth; U Dorwarth; G Steinbeck
Journal:  Herz       Date:  1999-10       Impact factor: 1.443

5.  No incremental benefit of multisite atrial pacing compared with right atrial pacing in patients with drug refractory paroxysmal atrial fibrillation.

Authors:  T Levy; S Walker; S Rex; J Rochelle; V Paul
Journal:  Heart       Date:  2001-01       Impact factor: 5.994

Review 6.  Report of the NASPE/NHLBI Round Table on Future Research Directions in Atrial Fibrillation. North American Society of Pacing and Electrophysiology.

Authors:  S Saskena; M J Domanski; E J Benjamin; A J Camm; M D Ezekowitz; B J Gersh; J Jalife; G V Naccarelli; R E Vlietstra; D G Wyse
Journal:  J Interv Card Electrophysiol       Date:  2001-09       Impact factor: 1.900

7.  Automatic atrial anti-tachy pacing for the termination of spontaneous atrial tachyarrhythmias: clinical experience with a novel dual-chamber pacemaker.

Authors:  D Vollmann; J Stevens; A B Buchwald; C Unterberg
Journal:  J Interv Card Electrophysiol       Date:  2001-12       Impact factor: 1.900

Review 8.  Permanent pacing: new indications.

Authors:  M R Gold
Journal:  Heart       Date:  2001-09       Impact factor: 5.994

Review 9.  Endocavitary treatment of atrial fibrillation.

Authors:  S B Olsson; E I Hertervig; O Kongstad; C Meurling; S Yuan
Journal:  J Thromb Thrombolysis       Date:  1999-01       Impact factor: 2.300

10.  The importance of right atrial pacing electrode position and pacing configuration for intra-atrial and inter-atrial conduction times.

Authors:  W M Hartung; D Hartung; H Saad; A Mittag; D Mahnkopf; H U Klein; R Willems
Journal:  J Interv Card Electrophysiol       Date:  2000-06       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.