Literature DB >> 8771042

Sensitivity of femoral strain pattern analyses to resultant and muscle forces at the hip joint.

M Lengsfeld1, J Kaminsky, B Merz, R P Franke.   

Abstract

An automated geometrical preprocessor was developed with the aim of creating three-dimensional finite element models (FEM) of the human femur. On the basis of postprocessed computed tomography data, this preprocessor makes possible rapid, flexible and regular meshing with 'brick' elements. Three different material properties were modelled at the present stage of development. Sensitivity analyses demonstrated that the strain energy density (SED) patterns of the different femoral parts were most sensitive to the implementation of an iliotibial tract force. The variation of the resultant hip force and abductor force direction within the sagittal plane demonstrated a SED minimum at an anterior inclination of 13 degrees; the variation of the resultant force direction within the frontal plane demonstrated a minimum SED at a medial inclination of 21 degrees relative to the mechanical axis of the lower limb. The orientation of the connecting line between the surface-SED-peaks in the horizontal view was found to be most sensitive to the variation of the resultant force within the sagittal plane.

Entities:  

Mesh:

Year:  1996        PMID: 8771042     DOI: 10.1016/1350-4533(95)00033-x

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

1.  Comment on the publication "Three-dimensional ultrasound, biomicroscopy environmental and conventional scanning electron microscopy investigations of the human zonula ciliaris for numerical modelling of accommodation" by O. Stachs et al.

Authors:  Ronald A Schachar; Ali Abolmaali; Farhad Kamangar
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-03-08       Impact factor: 3.117

2.  A porous polymeric-hydroxyapatite scaffold used for femur fractures treatment: fabrication, analysis, and simulation.

Authors:  Saeid Esmaeili; Hossein Akbari Aghdam; Mehdi Motififard; Saeed Saber-Samandari; Amir Hussein Montazeran; Mohammad Bigonah; Erfan Sheikhbahaei; Amirsalar Khandan
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-08-16

3.  Insights into the age-related decline in the amplitude of accommodation of the human lens using a non-linear finite-element model.

Authors:  R A Schachar; A Abolmaali; T Le
Journal:  Br J Ophthalmol       Date:  2006-07-19       Impact factor: 4.638

4.  A comparative study of orthotropic and isotropic bone adaptation in the femur.

Authors:  Diogo M Geraldes; Andrew T M Phillips
Journal:  Int J Numer Method Biomed Eng       Date:  2014-04-21       Impact factor: 2.747

5.  Bone preserving level of osteotomy in short-stem total hip arthroplasty does not influence stress shielding dimensions - a comparing finite elements analysis.

Authors:  Rene Burchard; Sabrina Braas; Christian Soost; Jan Adriaan Graw; Jan Schmitt
Journal:  BMC Musculoskelet Disord       Date:  2017-08-07       Impact factor: 2.362

  5 in total