Literature DB >> 8770475

Comparisons of angiographic core laboratory analyses of phantom and clinical images: interlaboratory variability.

G J Beauman1, J H Reiber, G Koning, R A Vogel.   

Abstract

Centralized, quantitative coronary analysis (QCA) has become the standard for determining change in coronary anatomy in clinical investigations. QCA systems and laboratory methods, however, vary among core facilities, and analysis variability among angiographic core laboratories (ACL) has not be studied. We evaluated QCA accuracy and variability among active ACL, using differing QCA systems by comparing analyses of phantom and clinical cinefilm images. Automated, unedited analyses were performed on images of 11 plexiglass phantom lumens (0.67-5.05 mm) acquired under varying radiographic conditions. Analysis differences from actual luminal diameters ranged widely (+0.42 - (-)0.45 mm) among ACL. Measurement of diameters < 1.0 mm were overestimated and diameters > 3.0 mm were underestimated. Measurements of midrange diameters (> 1.0 mm and < 3.0 mm) were most comparable among ACL (93% within +/- 0.2 mm). Clinical image analysis was performed using differing QCA systems and laboratory methodology on 11 randomly selected study films. Comparative analyses revealed significant variability between laboratories in the assessment of minimal lumen diameter (0.22 +/- 0.38 mm P < 0.05). These data describe analysis variability among ACL and demonstrate a need for establishing ACL performance standards.

Mesh:

Year:  1996        PMID: 8770475     DOI: 10.1002/(SICI)1097-0304(199601)37:1<24::AID-CCD7>3.0.CO;2-6

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  3 in total

1.  Validation of an accurate method for three-dimensional reconstruction and quantitative assessment of volumes, lengths and diameters of coronary vascular branches and segments from biplane angiographic projections.

Authors:  E Wellnhofer; A Wahle; I Mugaragu; J Gross; H Oswald; E Fleck
Journal:  Int J Card Imaging       Date:  1999-10

2.  Inter- and intra-core laboratory variability in the quantitative coronary angiography analysis for drug-eluting stent treatment and follow up.

Authors:  Shigenori Ito; Kanako Kinoshita; Akiko Endo; Ryoko Kami; Yuko Kotake; Masato Nakamura
Journal:  Ther Adv Cardiovasc Dis       Date:  2020 Jan-Dec

3.  Angiographic core laboratory reproducibility analyses: implications for planning clinical trials using coronary angiography and left ventriculography end-points.

Authors:  Terje K Steigen; Cheryl Claudio; David Abbott; Michael Schulzer; Jeff Burton; Wayne Tymchak; Christopher E Buller; G B John Mancini
Journal:  Int J Cardiovasc Imaging       Date:  2007-12-12       Impact factor: 2.357

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.